PubMed Health⌕ Search

PubMed · 15357458

[A computer-aided image diagnosis and study system].

Abstract

The revolution in information processing, particularly the digitizing of medicine, has changed the medical study, work and management. This paper reports a method to design a system for computer-aided image diagnosis and study. Combined with some good idea of graph-text system and picture archives communicate system (PACS), the system was realized and used for "prescription through computer", "managing images" and "reading images under computer and helping the diagnosis". Also typical examples were constructed in a database and used to teach the beginners. The system was developed by the visual developing tools based on object oriented programming (OOP) and was carried into operation on the Windows 9X platform. The system possesses friendly man-machine interface.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Zhangyong Li, Zhengxiang Xie. 2004. [A computer-aided image diagnosis and study system].. https://pubmed.ncbi.nlm.nih.gov/15357458/

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Common errors in computer electrocardiogram interpretation.

OBJECTIVE: The aim of the study was to determine the frequency and nature of errors in computer electrocardiogram (ECG) reading. METHODS: The ECGs were collected in the tertiary care VA Hospital from both inpatients and outpatients. They were read by the electrocardiograph built-in computer software, and then reread by two cardiologists. Statistical analysis was performed using sensitivity, specificity, positive and negative predicted value to analyze the data. An error index was formulated as indicator of diagnostic accuracy. RESULTS: Out of 2072 ECGs, 776 (37.5%) were normal, and 1296 (62.5%) were abnormal. In 9.9% of all ECGs and in 15.9% of abnormal ECGs there were significant disagreements between the computer and cardiologists. The errors in diagnosis of arrhythmia, conduction disorders and electronic pacemakers accounted for 178 cases, or 86.4% of all errors. The rest was represented by misdetection of chamber enlargement (7 cases, 3.4%), misdiagnosis of ischemia and acute myocardial infarction (16 cases, 7.8%), and lead misplacement (5 cases, 2.4%). CONCLUSIONS: The most frequent errors in computer ECG interpretation are related to arrhythmias, conduction disorders, and electronic pacemakers. Computer ECG diagnosis of life threatening conditions e.g. acute myocardial infarction or high degree AV blocks are frequently not accurate (40.7% and 75.0% errors, respectively). Improvement in the diagnostic algorithms should focus on these areas. Error index is a convenient and informative tool for evaluation of diagnostic accuracy.

Diagnosis, Computer-Assisted↗

Automated detection of lung nodules in multidetector CT: influence of different reconstruction protocols on performance of a software prototype.

PURPOSE: To evaluate the accuracy of software for computer-aided detection (CAD) of lung nodules using different reconstruction slice thickness protocols in multidetector CT. MATERIALS AND METHODS: Raw image data sets for 15 patients who had undergone 16-row multidetector CT (MDCT) for known pulmonary nodules were reconstructed at a reconstruction thickness of 5.0, 2.0 and 1.0 mm with a reconstruction increment of 1.5, 1.0 and 0.5 mm, respectively. The "Nodule Enhanced Viewing" (NEV) tool of LungCare for computer-aided detection of lung nodules was applied to the reconstructed images. The reconstructed images were also blinded and then evaluated by 2 radiologists (A and B). Data from the evaluating radiologists and CAD was then compared to an independent reference standard established using the consensus of 2 independent experienced chest radiologists. The eligible nodules were grouped according to their size (diameter > 10, 5 - 10, < 5 mm) for assessment. Statistical analysis was performed using the receiver operating characteristic (ROC) curve analysis, t-test and two-rater Cohen's Kappa co-efficient. RESULTS: A total of 103 nodules were included in the reference standard by the consensus panel. The performance of CAD was marginally lower than that of readers at a 5.0-mm reconstruction thickness (AUC = 0.522, 0.517 and 0.497 for A, B and CAD, respectively). In the case of 2.0-mm reconstruction slices, the performance of CAD was better than that of the readers (AUC = 0.524, 0.524 and 0.614 for A, B and CAD, respectively). CAD was found to be significantly superior to radiologists in the case of 1.0-mm reconstruction slices (AUC = 0.537, 0.531 and 0.675 for A, B and CAD, respectively). The sensitivity at a reconstruction thickness of 1.0 mm was determined to be 66.99 %, 68.93 % and 80.58 % for A, B and CAD, respectively. The time required for detection was shortest for CAD at reconstruction slices of 1.0 mm (mean t = 4 min). The performance of radiologists was greatly enhanced when using CAD: sensitivity 91.26 % and 94.17 % for CAD+A and CAD+B, respectively (AUC = 0.889 and 0.917). CAD was most advantageous in the detection of nodules < 10 mm. CONCLUSION: At a 1.0-mm reconstruction thickness, CAD's ability to detect nodules < 10 mm is superior to that of radiologists and its relatively short evaluation time makes it a viable second reader.

Diagnosis, Computer-Assisted↗

A pulmonary nodule modeling tool as a diagnostic aid for lung HRCT images.

A lung model and a software tool were developed with the aim to help the radiologist in understanding the underlying nodule distribution modes in the lung, in spreading nodules on lung sections according to predefined distribution modes. For educational purpose lung elements can be easily highlighted using false colors. The fast execution times which allow the radiologist to test different nodule distributions and to choose, by comparison with CT, the likeliest one, makes it a helpful tool to determine the real diagnosis. Connected to a database containing final diagnoses, it should be a help for research in lung pathology.

Diagnosis, Computer-Assisted↗