Fast method development and rapid analysis using a screening approach for enantiomeric separations in capillary electrophoresis.

Abstract

In order to speed up the trial-and-error process during enantioselective capillary electrophoresis methods development, a systemized approach is proposed to develop methods by applying several screening methods in the search for an initial separation. Screening methods combine high selectivity with broad applicability and are applied to find an initial enantiomeric separation during early pharmaceutical development (pre-Phase 1 to Phase 1). The goal is to achieve enantiomeric separation rapidly in order to characterize the chiral purity of pharmaceutical products. Dedicated, highly efficient screening methods are suggested for basic, neutral, and acidic compounds. In these screening methods, multiple chiral selectors are applied in mixtures at different buffer pH values. For the compounds studied, the technique allows fast method development. Furthermore, it is potentially applicable to a wide range of low-molecular-weight compounds and permits rapid analysis at low cost, since runs are performed in inexpensive, bare silica capillaries using ordinary buffer systems with only typical cyclodextrins as the selector. Along with simplicity and robustness, the approach results in sufficient efficacy (i.e., it is easy, straightforward, and reproducible, with a high success rate). Typical pharmaceutical applications are described. The major advantage of the screening approach to methods development is the decrease in development cycle time. The total screening time for one compound was about 5.3 hr on one CE instrument.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

M Ilias Jimidar, Willy Van Ael, Rekha Shah, Dirk Redlich, Maurits De Smet. Fast method development and rapid analysis using a screening approach for enantiomeric separations in capillary electrophoresis.. https://pubmed.ncbi.nlm.nih.gov/15369174/

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

MALDI-TOF MS in lipidomics.

So far, matrix-assisted laser desorption and ionization time-of-flight mass spectrometry (MALDI-TOF MS) seemed to be nearly a synonym for protein analysis. However, there is growing evidence that this technique is also an useful tool in lipid analysis and lipidomics because of its fast, simple and convenient performance allowing to record mass spectra of cells, crude tissue or body fluid extracts or even intact tissue slices in a few minutes. On the negative side, however, the reproducibility of MALDI-TOF mass spectra depends significantly on the homogeneity of the co-crystals between matrix and analyte and different lipid classes are detected with different sensitivities. This is especially important because lipids with quaternary ammonia groups (e.g., GPCho) may prevent the detection of other lipid classes (e.g., GPEtn). This review starts with a short overview on traditional methods of lipid analysis with the focus on mass spectrometric methods and compares MALDI-TOF MS with other important ionization techniques. Afterwards, some landmarks in the development of MALDI-TOF MS will be introduced and some important examples in the field of tissue and body fluid lipid analysis will be discussed. This review ends with a short outlook and summary focusing on the advantages and drawbacks of MALDI-TOF MS in lipidomics.

Complex Mixtures↗

Structural characterization of phosphatidyl-myo-inositol mannosides from Mycobacterium bovis Bacillus Calmette Guérin by multiple-stage quadrupole ion-trap mass spectrometry with electrospray ionization. I. PIMs and lyso-PIMs.

We described a multiple-stage ion-trap mass spectrometric approach to characterize the structures of phosphatidylinositol and phosphatidyl-myoinositol mannosides (PIMs) in a complex mixture isolated from Mycobacterium bovis Bacillus Calmette Guérin. The positions of the fatty acyl substituents of PIMs at the glycerol backbone can be easily assigned, based on the findings that the ions arising from losses of the fatty acid substituent at sn-2 as molecules of acid and of ketene, respectively (that is, the [M - H - R(2)CO(2)H](-) and [M - H - R(2)CHCO](-) ions), are respectively more abundant than the ions arising from the analogous losses at sn-1 (that is, the [M - H - R(1)CO(2)H](-) and [M - H - R(1)CHCO](-) ions) in the MS(2) product-ion spectra of the [M - H](-) ions desorbed by electrospray ionization (ESI). Further dissociation of the [M - H - R(2)CO(2)H](-) and [M - H - R(1)CO(2)H](-) ions gives rise to a pair of unique ions corresponding to losses of 74 and 56 Da (that is, [M - H - R(x)CO(2)H - 56](-) and [M - H - R(x)CO(2)H - 74](-) ions, x = 1, 2), respectively, probably arising from various losses of the glycerol. The profile of the ion-pair in the MS(3) spectrum of the [M - H - R(2)CO(2)H](-) ion is readily distinguishable from that in the MS(3) spectrum of the [M - H - R(1)CO(2)H](-) ion and thus the assignment of the fatty acid substituents at the glycerol backbone can be confirmed. The product-ion spectra of the [M - H](-) ions from 2-lyso-PIM and from 1-lyso-PIM are discernible and both spectra contain a unique ion that arises from primary loss of the fatty acid substituent at the glycerol backbone, followed by loss of a bicyclic glycerophosphate ester moiety of 136 Da. The combined structural information from the MS(2) and MS(3) product-ion spectra permit the complex structures of PIMs that consist of various isomers to be unveiled in detail.

Complex Mixtures↗

Optimization of homonuclear 2D NMR for fast quantitative analysis: application to tropine-nortropine mixtures.

Quantitative analysis by (1)H NMR is often hampered by heavily overlapping signals that may occur for complex mixtures, especially those containing similar compounds. Bidimensional homonuclear NMR spectroscopy can overcome this difficulty. A thorough review of acquisition and post-processing parameters was carried out to obtain accurate and precise, quantitative 2D J-resolved and DQF-COSY spectra in a much reduced time, thus limiting the spectrometer instabilities in the course of time. The number of t(1) increments was reduced as much as possible, and standard deviation was improved by optimization of spectral width, number of transients, phase cycling and apodization function. Localized polynomial baseline corrections were applied to the relevant chemical shift areas. Our method was applied to tropine-nortropine mixtures. Quantitative J-resolved spectra were obtained in less than 3 min and quantitative DQF-COSY spectra in 12 min, with an accuracy of 3% for J-spectroscopy and 2% for DQF-COSY, and a standard deviation smaller than 1%.

Complex Mixtures↗