PubMed Health⌕ Search

PubMed · 15382296

Carinal resection.

Abstract

There are many challenges in performing carinal resection and, in particular, reconstruction. A better understanding of the safe limits of resection has contributed to the reduced mortality from anastomotic complications. Accurate selection of patients, a meticulous adherence to surgical precision, and optimal postoperative patient care have become mandatory to reduce the risk of the most serious complications, such as noncardiogenic pulmonary edema and suture dehiscence. With carinal resection for bronchogenic carcinoma, contemporary studies suggest that there are reasonable survival rates in the absence of involved mediastinal lymph nodes or distant metastatic disease. The role of neoadjuvant therapy for bronchogenic carcinoma involving the carina deserves further investigation; this type of therapy should be used with caution because of the deleterious effects on anastomotic healing.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Michael Lanuti, Douglas J Mathisen. 2004. Carinal resection.. https://doi.org/10.1016/s1547-4127(04)00011-8

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Role of fluid dynamics on the healing of an in vivo tissue engineered vascular graft.

A polyester (PET) reinforced fibrin-FN-VEGF-TGFbeta vascular graft, formed by a four-step preclotting technique of a porous PET arterial graft, shows the overlapping inflammation, proliferation, and remodeling steps of normal wound healing when implanted in the descending thoracic aorta (DTA) position in the dog, forming a surface layer of endothelial cells. While the DTA grafts readily healed (i.e., endothelialized), similar grafts implanted in the carotid-femoral artery position did not fully heal. Since the initial phases of healing were shown to be dependent upon the transport of blood-borne constituents to the graft surface, the extent of healing appears to be dependent on the fluid dynamics present in the artery-graft-artery construct. The length of the noncompliant graft, the construction of the anastomoses, bends in the construct, graft diameter, and graft compliance can affect the fluid dynamics in the implant, and thus the healing of the graft. This has clinical relevance for the testing and development of new vascular graft materials.

Anastomosis, Surgical↗

Comparison of the hemodynamics in 6mm and 4-7 mm hemodialysis grafts by means of CFD.

The aim of our study is to investigate with computational fluid dynamics (CFD) whether different arterial anastomotic geometries result in a different hemodynamics at the arterial (AA) and venous anastomosis (VA) of hemodialysis vascular access grafts. We have studied a 6mm graft (CD) and a 4-7 mm graft (TG). A validated three-dimensional CFD model is developed to simulate flow in the two graft types. Only the arterial anastomosis (AA) geometry differs. The boundary conditions applied are a periodic velocity signal at the arterial inlet and a periodic pressure wave at the venous outlet. Flow rate is set to 1,000 ml/min. The time dependent Navier-Stokes equations are solved. Wall shear stress (WSS), wall shear stress gradient (WSSG) and pressure gradient (PG) are calculated. Anastomotic flow is asymmetric although the anastomosis geometry is symmetric. The hemodynamic parameters, WSS, WSSG and PG, values at the suture line of the arterial anastomosis of the TG are at least twice as much as in the CD. Comparing the parameters at the two AA indicate that little flow rate increase introduces the risk of hemolysis in the TG whereas the CD is completely free of hemolysis. The hemodynamic parameter values at the venous anastomosis of the CD are 24 till 35% higher compared to the values of the TG. WSS values (> 3 Pa) in the VA are in the critical range for stenosis development in both graft geometries. The zones where the parameters reach extreme values correspond to the locations where intimal hyperplasia formation is reported in literature. In all anastomoses, the hemodynamic parameter levels are in the range where leucocytes and platelets get activated. Our simulations confirm clinical results where TG did not show a better outcome when compared to the CD.

Anastomosis, Surgical↗

Numerical modelling of Newtonian and non-Newtonian representation of blood in a distal end-to-side vascular bypass graft anastomosis.

The proliferation of disease at the bed of the distal junction of an end-to-side anastomosis is attributed to abnormal wall shear stress (WSS) distribution. WSS is proportional to the viscosity and shear rate of the flowing fluid. Blood is characterised by a shear rate dependent viscosity. Various constitutive equations have been developed to represent the shear rate dependence of blood viscosity: Newtonian, Carreau, Power law, Carreau-Yasuda, Bi-exponential, Cross, Modified Cross, Herschel-Bulkley, etc. In the femoral artery, the instantaneous shear rate varies from 1-1200 s(-1) over a cardiac cycle. An idealised, 45 degrees rigid, 6mm diameter, end-to-side femoral anastomosis was modelled on a Computational Fluid Dynamic software package Fluent 6.0. A steady flow of 0.15 and 0.01 m/s was applied to the inlet to model high and low wall shear rate environments respectively. Blood was modelled using the various constitutive equations. The resulting WSS distribution on the bed of the artery was then obtained. At high shear rates there was no significant difference between WSS distribution. At low shear rates there were qualitative differences of up to 300%. In conclusion, the choice of blood constitutive equation has to be based on the particular situation under study e.g. flow rate, steady/unsteady flow, and geometry.

Anastomosis, Surgical↗