A method to quantitatively detect H-ras point mutation based on electrochemiluminescence.

Abstract

Conventional methods for point mutation detection are usually multi-stage, laborious, and need to use radioactive isotopes or other hazardous materials, and the assay results are often semi-quantitative. In this work, a protocol for quantitative detection of H-ras point mutation was developed. Electrochemiluminescence (ECL) assay was coupled with restriction endonuclease digestion directly from PCR products. Only the wild-type amplicon containing the endonuclease's recognition site can be cut off, and thus cannot be detected by ECL assay. Using the PCR-ECL method, 30 bladder cancer samples were analyzed for possible point mutation at codon 12 of H-ras oncogene. The results show that the detection limit for H-ras amplicon is 100 fmol and the linear range is more than three orders of magnitude. The point mutation was found in 14 (46.7%) out of 30 bladder cancer samples. The experiment results demonstrate that the PCR-ECL method is a feasible quantitative approach for point mutation detection due to its safety, high sensitivity, and simplicity.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Debin Zhu, Da Xing, Xingyan Shen, Jinfeng Liu. 2004-11-12. A method to quantitatively detect H-ras point mutation based on electrochemiluminescence.. https://doi.org/10.1016/j.bbrc.2004.09.121

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Development and validation of a liquid chromatographic method for determination of enantiomeric purity of citalopram in bulk drugs and pharmaceuticals.

A simple, rapid and robust LC method for enantiospecific separation and determination of citalopram in drugs and pharmaceuticals was developed using UV and polarimetric detectors connected in series. Baseline separation with resolution > or = 3.0 was achieved within 20 min on Chiralcel OD-H (250 mm x 4.6 mm) 5 microm column using a mobile phase containing of n-hexane:2-propanol:triethylamine (TEA) (95:05:0.1 v/v/v) at a flow rate of 1.0 ml/min at 25 degrees C. Effects of 2-propanol, triethylamine and temperature on enantioselectivity and resolution of the enantiomers were evaluated. Clopidogrel hydrogen sulphate was used as an internal standard (IS) for quantitative determinations using UV detector at 240 nm. Polarimetric detector was used for identification of enantiomers. The limits of detection (LOD) and quantification (LOQ) were 0.5 and 1.3 microg/ml respectively for both the enantiomers. The linearity of the method was in the range of 50-600 microg/ml with r2 > 0.9999. The inter- and intra-day assay precision was less than 0.63% (%R.S.D.) and recoveries were in the range 99.38-100.41%. The method was validated and found to be suitable for determination enantiomeric purity of citalopram in bulk drugs and pharmaceutical formulations.

Calibration↗

Real-time endpoint monitoring and determination for a pharmaceutical salt formation process with in-line FT-IR spectroscopy.

An application of Fourier transform infrared (FT-IR) spectroscopy equipped with an attenuated total reflectance (ATR) probe for in-line monitoring of a hydrochloride (HCl) salt formation process of 4-{1-methyl-2-piperidin-4-yl-4-[3-(trifluorometryl)phenyl]-1H-imidazol-5-yl}-N-[(1S)-1-phenylethyl]pyridine-2-amine (freebase), an active pharmaceutical ingredient as a P38 MAP kinase inhibitor, is described. The freebase forms both mono- and bis-HCl salts due to its structural features. The mono-HCl salt is the desired product but the bis-salt is an impurity. The key to maximizing the product yield and minimizing the impurity level is to monitor the salt-forming reaction and to terminate it at the correct HCl charge amount. The process analytical technology (PAT) provided real-time data for process control and overcame the limitations that had been previously encountered by other analytical instrumentations, such as high-performance liquid chromatography and titration. Two qualitative approaches for reaction endpoint determination were employed. In the first approach, changes in the concentration of the freebase and bis-salt were monitored via the first derivative concentration profiles. The flat point in the freebase profile and the rise in the bis-salt profile were used as a detection bracket for the endpoint of HCl charging. In the second approach, principal component analysis (PCA) was used to classify the status of the process based on a spectral library consisting of spectra collected around the endpoint. Results indicated that both methods provided adequate accuracy for endpoint control in a small window between 1.0 and 1.05 HCl to freebase mole ratio. Both methods were used to support a scaled up process. Three batches of MAP mono-HCl salt formation were successfully controlled and prepared.

Calibration↗

Determination of lignin by size exclusion chromatography using multi angle laser light scattering.

A method was developed using high-performance size exclusion liquid chromatography (HPSEC) with multi-angle laser light scattering (MALLS), quasi-elastic light scattering (QELS), interferometric refractometry (RI) and UV detection to characterize and monitor lignin. The combination proved very effective at tracking changes in molecular conformation of lignin molecules over time; i.e. changes in molecular weight distribution, radius of gyration, and hydrodynamic radius. Until this study, UV detection (280 nm) had been the primary lignin determination method for chromatography. Three different HPLC columns were used to study the effects of pH, flow conditions, and mobile phase compositions (dimethyl sulphoxide, water, 0.1M NaOH, and lithium bromide) on the chromatography of lignin. Since light scattering accuracy is highly dependent on solute concentration, both the UV and RI detectors were calibrated for use as concentration detectors. Shodex Asahipak GS-320 HQ column with 0.1M NaOH (pH 12.0) run at 0.5 ml/min was found to give the highest separation and most consistent recovery. The study also revealed that the lignin aggregated at pH below 8.5. This aggregation was detected only by MALLS and was not observed on UV or RI detectors. It is very important to take this loss in apparent concentration due to aggregation into consideration before collecting reliable depolymerization data.

Calibration↗