PubMed Health⌕ Search

PubMed · 15487051

Using dispersion to detect binding.

Abstract

The source did not provide an abstract. Follow the original record for more information.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Katie Cottingham. 2004-10-01. Using dispersion to detect binding.. https://doi.org/10.1021/ac041634h

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

One- and two-photon induced fluorescence of Pacific Blue-labeled human serum albumin deposited on different core size silver colloids.

We studied one- and two-photon induced fluorescence of Pacific Blue (PB)-labeled human serum albumin (HSA) in the presence of different size silver colloids. The PB fluorescence emission intensity was observed with small (30-40 nm) and large (about 120 nm) colloids and compared with PB emission in absence of colloids. For the system with a small core size colloids we did not detect any fluorescence enhancement with one-photon excitation and the enhancement observed with two-photon excitation was about 2.5-fold. In contrast, for large silver colloids we observed about a 2-fold increase in PB fluorescence brightness for one-photon excitation, and the enhancement with two-photon excitation excided 13-folds. Much stronger increases in brightness observed with two-photon excitation, compared to one-photon excitation, indicate a dominant role of enhanced local field in fluorescence enhancement on silver colloids in solutions.

Colloids↗

Colloid probe AFM investigation of the influence of cross-linking on the interaction behavior and nano-rheology of colloidal droplets.

The repulsive forces between a glass sphere and immobilized colloidal droplets of poly(dimethylsiloxane) (PDMS) (with various levels of internal cross-linking) have been determined in aqueous solution using colloid probe atomic force microscopy. On initial surface approach, droplet deformation is negligible and interaction forces resemble those expected for electrical double layer interaction of rigid spheres. Upon further approach, droplet flattening results in forces that deviate below rigid body electrical double layer interaction. The extent of droplet deformation has been determined in terms of the deviation from hard-sphere interaction. Droplet deformability is strongly dependent on the droplet cross-linking level and hence controlled by some combination of the bulk rheological and interfacial properties of the droplets. Droplet nano-rheology has been determined from the extent of force curve hysteresis. For liquidlike droplets, with low levels of cross-linking, no force curve hysteresis is observed and the elastic deformation may be described by a single spring constant, which is controlled by the interfacial properties. For highly cross-linked droplets, the extent of deformation is controlled by the droplet's bulk rheology rather than the interfacial properties. Upon retraction of the surfaces, force curve hysteresis is observed and is due to the viscoelastic response of the PDMS. The extent of hysteresis is dependent on the rate of approach/retraction and the loading force and has been theoretically analyzed to determine nano-rheological parameters that describe droplet relaxation processes. Elastic moduli and relaxation times of the PDMS droplets vary over several orders of magnitude as a function of cross-linking.

Colloids↗