Use of post-and-core restorations has changed markedly in the past several decades. Current use and research supports techniques using tooth-colored, fiber-reinforced resin-based composite posts or titanium alloy posts cemented with resin cement, followed by resin-based composite build-ups. Although fiber-reinforced resin-based composite posts appear to be very promising, long-term clinical observation is needed. I have made suggestions about when to use posts, what type of post to use and how to use them.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Gordon J Christensen. 2004. Post concepts are changing.. https://doi.org/10.14219/jada.archive.2004.0406

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Rheological characterization of composites using a vertical oscillation rheometer.

OBJECTIVES: The purpose of this study was to investigate the viscoelastic properties related to the handling characteristics of composites. METHODS: A custom-designed vertical oscillation rheometer (VOR) was used for the rheological measurements of composites. The VOR consists of three parts: (1) a measuring unit, (2) a deformation induction unit, and (3) a force-detecting unit. Two medium-viscous composites, Z100 and Z250, and two packable composites, P60 and SureFil, were tested. A dynamic oscillatory test was used to evaluate the storage modulus (E'), loss modulus (E''), and loss tangent (tan delta) of the composites as a function of frequency (omega) from 0.1 to 20Hz at 23 degrees C. RESULTS: The E' and E'' increased with increasing frequency and showed differences in magnitude among brands. The complex moduli E* of the composites at omega=2 Hz, normalized to that of Z100, were 2.16 (Z250), 4.80 (P60), and 25.21 (SureFil). The magnitudes and frequency characteristic of loss tangent differed significantly among brands. The relationship among the complex modulus E*, the phase angle delta, and the frequency omega was represented by the frequency domain phasor form E*(omega)e(idelta)=E*(omega) angledelta. SIGNIFICANCE: The viscoelasticities of composites, which influence handling characteristics, are significantly different among brands. The VOR is a relatively simple device for the dynamic rheological measurement of dental composites. The loci of the frequency domain phasor plots in a complex plane are a valuable method of representing the viscoelastic properties of composites.

Composite Resins↗

Resistance to fracture and structural characteristics of different fiber reinforced post systems.

OBJECTIVES: The aim of this study was to investigate the ultrastructure and resistance to fracture of eight different types of fiber post, and to verify the existence of a correlation between structural characteristics and flexural strength. METHODS: Eight types of fiber post were selected for this study. Fiber Kor (Jeneric-Pentron), Para Post Fiber White (Colténe), Luscent Anchor (Dentatus), Twin-Luscent Anchor (Dentatus), Style Post (Metalor), DT White-Post (VDW), DT Light-Post (VDW) and ER Dentin Post (Brasseler). Ten posts of each experimental group were selected for a three-point bending test, and one was processed for SEM evaluation. A universal testing machine loading at an angle of 90 degrees was employed for the three-point bending test. The test was carried out until fracturing of the post. After fracture testing, the posts with the highest and the lowest values of flexural strength of each system were additionally processed for SEM analysis. SEM evaluation was performed using a PC-measurement program to assess the fiber/matrix ratio and fiber dimensions. RESULTS: The fracture load of the tested systems ranged from 60 to 96 N and the flexural strength from 565 to 898 MPa. DT White-Post and DT Light-Post (898 and 842 MPa, respectively) had significantly higher flexural strengths than the other posts. Style Post (565 MPa) showed a significantly lower flexural strength than all other posts. The differences in fiber diameter ranged from 8.2 to 21 microm and for the fiber/matrix ratio from 41 to 76%. Of the various structural characteristics investigated, only the fiber/matrix ratio showed a significant correlation to the flexural strength (r=0.922, p=0.003). SIGNIFICANCE: The FRC-posts investigated displayed significant differences with regard to fracture load and flexural strength. A strong and significant linear correlation between the fiber/matrix ratio and the flexural strength was found.

Composite Resins↗

Composite resins. A review of the materials and clinical indications.

The aim of this work is to present the different components of the composites currently used in dentistry and furnish dentists with a basis that can provide criteria for choosing one or another to suit their therapeutic requirements. Most composites used in dentistry are hybrid materials, so-called because they are composed of polymer groups reinforced by an inorganic phase of glass fillers with different compositions, particle sizes and fill percentages. Flowable or condensable composites have attempted to provide an answer to certain functional requirements, although they have not been too successful at improving properties. Turning to polymerisation initiators, both halogen lamps, whether conventional or high intensity, and LED curing lights which provide a gradual increase in light intensity are very useful for reducing shrinkage of the composite material. The clinical choice of a composite must consider whether priority should be given to mechanical or aesthetic requirements: if mechanical considerations are paramount the material with the greatest volume of filler will be chosen; if aesthetic considerations predominate, particle size will be the most important factor. Additional components such as opaques and tints make it possible to improve the aesthetic results. Equally, the spread of other therapeutic procedures, such as tooth bleaching, has made it necessary to design composite materials in shades that are suitable for the special colour situations found in teeth treated by these methods.

Composite Resins↗