PubMed Health⌕ Search

PubMed · 15508069

Making structures for cell engineering.

Abstract

This is a mainly historical account of the events, methods and artifacts arising from my collaboration with Adam Curtis over the past twenty years to make exercise grounds for biological cells. Initially the structures were made in fused silica by photo-lithography and dry etching. The need to make micron-sized features in biodegradable polymers, led to the development of embossing techniques. Some cells response to grooves only a few tens of nanometers deep--this led to a desire to find the response of cells to features of nanometric size overall. Regular arrays of such features were made using electron beam lithography for definition of the pattern. Improvements were made in the lithographic techniques to allow arrays to be defined over areas bigger than 1 cm2. Structures with microelectrodes arranged inside guiding grooves to allow the formation of sparse predetermined networks of neurons were made. It is concluded that the creation of pattern, as in vivo, in assemblies of regrown cells in scaffolds may well be necessary in advanced cell engineering applications.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

C D W Wilkinson. 2004-10-22. Making structures for cell engineering.. https://doi.org/10.22203/ecm.v008a03

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Preparation of hybrid scaffold from fibrin and biodegradable polymer fiber.

A biodegradable hybrid scaffold was prepared from fibrin and poly(glycolic acid) (PGA) fiber. Mixed fibrinogen and thrombin solution homogeneously dispersed in the presence of various amounts (0, 1.5, 3.0, and 6.0mg) of PGA fiber was freeze-dried to obtain fibrin sponges with or without PGA fiber incorporation. By scanning electron microscopy observation, the fibrin sponges had an interconnected pore structure, irrespective of the amount of PGA fiber incorporated. PGA fiber incorporation enabled the fibrin sponges to significantly enhance their compression strength. In vitro cell culture studies revealed that the number of L929 fibroblasts initially attached was significantly larger for any fibrin sponge with PGA fiber incorporation than for the fibrin sponge without PGA fiber. The shrinkage of sponges after cell seeding was suppressed by fiber incorporation. It is possible that the shrinkage suppression of sponges maintains their intraspace, resulting in the superior cell attachment of a sponge with PGA fiber incorporation. After subcutaneous implantation into the backs of mice, the residual volume of a fibrin sponge with PGA fiber incorporation was significant compared with that of a fibrin sponge without PGA fiber. Larger number of cells infiltrated deep inside the fibrin sponges with PGA fiber incorporation implanted subcutaneously. It is concluded that the fibrin sponge reinforced by fiber incorporation is a promising three-dimensional scaffold of cells for tissue engineering.

Absorbable Implants↗

Influence of copolymer composition of polylactide implants on cranial bone regeneration.

Biodegradable polymers have become useful auxiliary materials for the functional and structural restoration of bone deficiencies. Commercial implants from poly(L/DL-lactide) 70:30 are used clinically for fracture fixation in regions of low load. Implants manufactured from poly(L/DL-lactide) 80:20 are currently being investigated experimentally. The higher degree of crystallinity results in a higher chemical strength and loading capacity which promises advantages for long-term implantation. In this study implants from these two copolymers were applied to promote bone regeneration of bilateral, full thickness, circular cranial defects in 16 adult New Zealand white rabbits. The defects were covered with melt extruded and laser cut polylactide burr hole covers epicranially and endocranially in direct contact to the dura. The defect spaces were kept open with a spacer which created a hollow chamber. Both materials were implanted in each animal. Bone seeking fluorochromes were used to assess the pattern of bone growth. After eight weeks bone regeneration in the defects was assessed radiologically, histologically and by fluorescence microscopy. During the eight weeks observation period the application of a hollow chamber design resulted in almost complete cranial defect healing, whereby the copolymer composition had no effect on the amount or the morphology of the regenerate. The dura mater showed no adverse tissue reactions during these early stages of implantation. Eight weeks is only a short period in the lifetime of the tested polymers and complete bone regeneration can only be expected after complete polymer degradation. Long-term studies or accelerated degradation studies are required to confirm the expected advantages of poly(L/DL-lactide) 80:20.

Absorbable Implants↗

Gas foamed open porous biodegradable polymeric microspheres.

Highly open porous biodegradable polymeric microspheres were fabricated for use as injectable scaffold microcarriers for cell delivery. A modified water-in-oil-in-water (W1/O/W2) double emulsion solvent evaporation method was employed for producing the microspheres. The incorporation of an effervescent salt, ammonium bicarbonate, in the primary W1 droplets spontaneously produced carbon dioxide and ammonia gas bubbles during the solvent evaporation process, which not only stabilized the primary emulsion, but also created well inter-connected pores in the resultant microspheres. The porous microspheres fabricated under various gas foaming conditions were characterized. The surface pores became as large as 20 microm in diameter with increasing the concentration of ammonium bicarbonate, being sufficient enough for cell infiltration and seeding. These porous scaffold microspheres could be potentially utilized for cultivating cells in a suspension manner and for delivering the seeded cells to the tissue defect site in an injectable manner.

Absorbable Implants↗