PubMed Health⌕ Search

PubMed · 15508146

Point spread function mapping with parallel imaging techniques and high acceleration factors: fast, robust, and flexible method for echo-planar imaging distortion correction.

Abstract

Echo-planar imaging (EPI) is an ultrafast magnetic resonance (MR) imaging technique prone to geometric distortions. Various correction techniques have been developed to remedy these distortions. Here improvements of the point spread function (PSF) mapping approach are presented, which enable reliable and fully automated distortion correction of echo-planar images at high field strengths. The novel method is fully compatible with EPI acquisitions using parallel imaging. The applicability of parallel imaging to further accelerate PSF acquisition is shown. The possibility of collecting PSF data sets with total acceleration factors higher than the number of coil elements is demonstrated. Additionally, a new approach to visualize and interpret distortions in the context of various imaging and reconstruction methods based on the PSF is proposed. The reliable performance of the PSF mapping technique is demonstrated on phantom and volunteer scans at field strengths of up to 4 T.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

M Zaitsev, J Hennig, O Speck. 2004. Point spread function mapping with parallel imaging techniques and high acceleration factors: fast, robust, and flexible method for echo-planar imaging distortion correction.. https://doi.org/10.1002/mrm.20261

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Striping artifact removal in VisiumHD data through nuclear counts modeling.

MOTIVATION: 10x Genomics VisiumHD enables spatial transcriptomics at 2 µm × 2 µm resolution but exhibits slide-specific, non-periodic striping artifacts due to lane-width variability. These multiplicative row/column effects distort bin total counts and can bias downstream analyses. The state-of-the-art destriping approach is the normalization procedure used as a preprocessing step in bin2cell; it applies sequential high-quantile row- then column-wise normalization, which is asymmetric and can introduce edge effects/macro-stripes and distortions of large-scale total-count structure. RESULTS: We propose a statistical destriping approach that leverages nuclei segmentation from the co-registered H&E image. Assuming transcript abundance is constant within each nucleus, we model bin counts with a negative binomial distribution whose mean is a product of a nucleus-specific concentration and row- and column-specific stripe-factors reflecting lane-width variation. We fit all parameters in a generalized linear modeling framework with cross-validated regularization on stripe-factors and iterative dispersion estimation, and use the fitted parameters to correct the observed counts into a destriped image. On synthetic data with known ground truth, our method improves stripe-factor estimation accuracy and reduces error in corrected counts relative to bin2cell and bin2cell-derived baselines. Across four public VisiumHD slides, it consistently lowers striping intensity while substantially better preserving biological signal present in the large-scale global count structure and avoiding the artifacts introduced by other methods. AVAILABILITY AND IMPLEMENTATION: All source code and links to publicly available data used for this study are available at https://github.com/paolamalsot/destriping-GLM.

Artifacts↗

Surface EMG measurements during fMRI at 3T: accurate EMG recordings after artifact correction.

In this experiment, we have measured surface EMG of the first dorsal interosseus during predefined submaximal isometric contractions (5, 15, 30, 50, and 70% of maximal force) of the index finger simultaneously with fMRI measurements. Since we have used sparse sampling fMRI (3-s scanning; 2-s non-scanning), we were able to compare the mean amplitude of the undisturbed EMG (non-scanning) intervals with the mean amplitude of the EMG intervals during scanning, after MRI artifact correction. The agreement between the mean amplitudes of the corrected and the undisturbed EMG was excellent and the mean difference between the two amplitudes was not significantly different. Furthermore, there was no significant difference between the corrected and undisturbed amplitude at different force levels. In conclusion, we have shown that it is feasible to record surface EMG during scanning and that, after MRI artifact correction, the EMG recordings can be used to quantify isometric muscle activity, even at very low activation intensities.

Artifacts↗

The novel red-fluorescent probe DAR-4M measures reactive nitrogen species rather than NO.

INTRODUCTION: Several fluorescent probes were designed for the measurement of nitric oxide (NO), however, questions arose regarding their specificity and sensitivity in biological samples. In the present study we tested the reaction of a novel rhodamine-based chromophore diaminorhodamine-4M (DAR-4M) with NO and other reactive nitrogen and oxygen species. METHODS: We performed fluorometry in 96-well plates in a cell-free buffer with similar ion concentrations as the cytoplasm. Dose-response curves were generated using various NO donors and reactive nitrogen and oxygen species. The effects were compared between the red-fluorescent DAR-4M and its green-fluorescent counterpart 4-amino-5-methylamino-2',7'-difluorofluorescein (DAF-FM). RESULTS: DAR-4M had a markedly higher fluorescence yield to NO donors than DAF-FM, while both probes had a comparable threshold of sensitivity (in the range of 0.1 mM nitroprusside). Both dyes reacted with various NO donors in a dose-dependent manner, while superoxide, hydrogen peroxide, peroxynitrite, or nitroxyl failed to change the fluorescence intensity of the probes. DAR-4M was potentiated in the presence of peroxynitrite to react with low levels of NO donors in a similar manner to DAF-FM. DISCUSSION: We conclude that DAR-4M is a suitable red-fluorescent probe for the qualitative assessment of reactive nitrogen species production, but not specific for NO. Quantitative comparisons among samples is inappropriate since the fluorescent yield is affected by the presence of other oxidants in the sample.

Artifacts↗