PubMed Health⌕ Search

PubMed · 15509983

A sponge model for flap surgery.

Abstract

The source did not provide an abstract. Follow the original record for more information.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Tayfun Turkaslan, Zafer Ozsoy, Hakan Ozcan. 2004. A sponge model for flap surgery.. https://pubmed.ncbi.nlm.nih.gov/15509983/

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Finite element analysis of a transmandibular implant.

Finite element analysis (FEA) was used to study the influence of bony height and baseplate effect on the transmandibular implant (TMI). FEA was used to assess the stress distribution in the mandible, with and without a baseplate. Forces were applied to the center of a bar space. The von Mises stress (SEQV) was displayed in bone, and shear stress also was measured. Tensile stress was always seen at the so-called saddle area; compressive stress was seen at the inferior border. Tensile strain at the saddle area of a 6-mm height mandible is always 9.1 times greater (corresponding to more SEQV) than that of an 18-mm mandible. At same bone heights, saddle area stresses are similar with or without a baseplate. However, stress at the lateral transossseous post interface with bone was significantly different between different bone height groups. Shear stress around the lateral transossseous post was smaller than does the SEQV of the same site. Decreased bone height dramatically increases stress at the saddle area independent of the baseplate presence. These data suggest that bone apposition is found in the severely atrophic mandibles. Thus, there is no need for a baseplate in a slight to mild atrophic mandible.

Biomechanical Phenomena↗

The relationship between shoulder torques and the perception of muscular effort in loaded reaches.

The objective of this study was to define the quantitative relationship between external dynamic shoulder torques and calibrated perceived muscular effort levels for load delivery tasks, for application in job analyses. Subjects performed a series of loaded reaches and, following each exertion, rated their perceived shoulder muscular effort. Motion and task physical requirements data were processed with a biomechanical upper extremity model to calculate external dynamic shoulder torques. Calculated torque values were then statistically compared to reported calibrated perceived muscular effort scores. Individual subject torque profiles were significantly positively correlated with perceived effort scores (r2 = 0.45-0.77), with good population agreement (r2 = 0.50). The accuracy of the general regression model improved (r2 = 0.72) with inclusion of factors specific to task geometry and individual subjects. This suggests two major conclusions: 1) that the perception of muscular shoulder effort integrates several factors and this interplay should be considered when evaluating tasks for their impact on the shoulder region; 2) the torque/perception relationship may be usefully leveraged in job design and analysis.

Biomechanical Phenomena↗

Kinematic response characteristics of the CAREN moving platform system for use in posture and balance research.

The CAREN system is a new and unique device for use in postural and balance research in clinical settings due to its ability to independently perturb the support surface in each of six degrees of freedom. Users of this system need knowledge of its technical performance which is not available. The aim of this study was to determine the technical performance of the CAREN system by defining its kinematic response characteristics to two commonly used input functions (sine and ramp) for each of its six translational and rotational axes. The translational and rotational displacement, velocity and acceleration limits of the CAREN system suggest that it is a mid-range system with regard to single degree of freedom moving platform devices reported in the literature. The maximum average displacement cross-talk was 1.5% of the viable working range in any specified direction. The maximum average velocity cross-talk was 3.3% of its maximum velocity in any specified direction. The CAREN system was able to respond to ramp input functions within its displacement and velocity limits although, for short duration ramps, there was evidence that target velocity was not reached. It is concluded that the CAREN system is an appropriate device for postural and balance research with some unique features. This specification of its technical performance should help researchers to identify the tasks for which it is most suitable.

Biomechanical Phenomena↗