PubMed Health⌕ Search

PubMed · 15518233

Modelling the Rayleigh match.

Abstract

We use the photopigment template of Baylor et al. (1987) to define the set of Rayleigh matches that would be satisfied by a photopigment having a given wavelength of peak sensitivity (lambda(max)) and a given optical density (OD). For an observer with two photopigments in the region of the Rayleigh primaries, the observer's unique match is defined by the intersection of the sets of matches that satisfy the individual pigments. The use of a template allows us to illustrate the general behavior of Rayleigh matches as the absorption spectra of the underlying spectra are altered. In a plot of the Y setting against the red-green ratio (R), both an increase in lambda(max) and an increase in optical density lead to an anticlockwise rotation of the locus of the matches satisfied by a given pigment. Since both these factors affect the match, it is not possible to reverse the analysis and define uniquely the photopigments corresponding to a specific Rayleigh match. However, a way to constrain the set of candidate photopigments would be to determine the trajectory of the change of match as the effective optical density is altered (by, say, bleaching or field size).

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

P B M Thomas, J D Mollon. Modelling the Rayleigh match.. https://doi.org/10.1017/s095252380421344x

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Diagnosing protan heterozygosity using the Medmont C-100 colour vision test.

BACKGROUND: A surprisingly high 15 per cent of women in Caucasian societies are carriers of the genes for abnormal colour vision but there is no clinical method to identify them. It has long been known that heterozygotes for the protan colour vision deficiencies can demonstrate a reduced luminous sensitivity to red light. This is known as Schmidt's sign, which is thought to arise from mosaicism (Lyonisation). The Medmont C-100 colour vision test measures relative spectral sensitivity using flicker photometry to differentiate protans and deutans. It should be able to diagnose Schmidt's sign. METHOD: We tested six known protan heterozygotes (four whose sons have a protan colour vision deficiency and two whose fathers are protan) with the Medmont C-100 test. RESULTS: All six heterozygotes made average settings of -1.75 or more negative at the Medmont C-100 test, settings which are at or beyond the boundary of the distribution of settings made by observers with normal colour vision. There have been two previous cases reported in the literature of protan heterozygotes, who made protan settings on the Medmont C-100 or its predecessor test, the OSCAR. We also tested six daughters of the known heterozygotes, 50 per cent of whom are likely to be heterozygotes. Four of the six (66 per cent) made protan settings on the Medmont C-100. The other two made normal 0.0 settings. CONCLUSION: We conclude that the Medmont C-100 can be used clinically to diagnose carriers of protan colour vision deficiency.

Color Perception Tests↗