The theoretical effect of measured wavefront diameter on estimating peripheral wavefront data.

Abstract

PURPOSE: To compare the difference between wavefront data measured in the periphery and that calculated from estimations using a smaller measured region. METHODS: A total of 32 eyes were measured using the Alcon LADARWave aberrometer (Alcon Laboratories Inc, Fort Worth, Tex). Aberrations were measured through a dilated pupil to the 6th order at a 6.5-mm diameter. Data were then "clipped" to 5.0, 5.5, and 6.0 mm, and each of these smaller diameter wavefronts was used to estimate the larger diameter wavefront coefficients. The measure of interest was the mean and range of error between the estimated and measured values, and how they varied for the different diameters of known data. RESULTS: The differences in both the mean and range of error were inversely correlated to the diameter of the region of known data. As this region grew smaller, the region estimated grew larger, with resultant larger mean errors. At 5 mm, the estimated zone was an annulus of 0.75-mm width; in this case the estimated higher order aberrations were 60% higher than those measured, with a range of 40% lower to 300% higher. At 5.5 mm and 6.0 mm, these differences were much smaller, but statistically significant. The differences were greatest when significant peripheral aberrations were measured, as can occur with post-laser in situ keratomileusis eyes. CONCLUSION: Basing a treatment on an estimation of the peripheral wavefront may lead to an inaccurate ablation profile. The inaccuracy increases as the size of the measured wavefront decreases relative to the planned ablation zone. The inaccuracy is also greatest when significant peripheral aberrations are present. Refractive surgery systems should only treat optical zones that are smaller than or equal to the diameter of the measured wavefront.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Roger Steinert. The theoretical effect of measured wavefront diameter on estimating peripheral wavefront data.. https://doi.org/10.3928/1081-597x-20040901-36

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

The variable expression of keratoconus within monozygotic twins: dundee University Scottish Keratoconus Study (DUSKS).

INTRODUCTION: As part of a longitudinal observational prospective study (Dundee University Scottish Keratoconus Study, DUSKS) a caucasian female subject was identified with keratoconus affecting both corneas. Of interest was that the subject's mother was a monozygotic twin, however, the mother was reportedly unaffected by keratoconus, although her sister (the subject's aunt) had been diagnosed with keratoconus. METHOD: Computer video-keratoscopy (CVK) was undertaken was on this family to clarify this apparent discordance. RESULTS: CVK demonstrated the variable expression of the keratoconic phenotype, by identifying evidence of subclinical keratoconus in the 'unaffected' twin. CONCLUSION: So far only one set of monozygotic twins with keratoconus have been reported within the UK, this paper reports a second. Since CVK has been available the majority agree on concordance of keratoconus expression but not all, including this study. If monozygotic twin studies demonstrate heterogeneity of keratoconus this may at least explain the contradictory data that exists within the literature and why the inheritance pattern of keratoconus is still unclear in 2005.

Corneal Topography↗

Comatic aberration as a cause of monocular diplopia.

Three patients (5 eyes) presented with complaints of monocular diplopia and no history of ocular trauma or surgery. The patients had comprehensive neuroophthalmic evaluation including manifest refraction, anterior segment and dilated fundus examination, and corneal topography. All patients also had wavefront analysis using the LADARWave system (Alcon). Two patients (4 eyes) also had hard contact lens overrefraction. The patients had a normal initial examination including corneal topography. One patient (2 eyes) did not experience resolution of diplopia with pinhole. No eye improved with manifest refraction or hard contact lens overrefraction. However, each patient had a significant amount of coma on wavefront analysis. Moreover, eyes with horizontal diplopia had horizontal coma and eyes with vertical diplopia had vertical coma as measured with the wavefront device. Higher-order optical aberrations such as coma may be associated with monocular diplopia. Wavefront technology may be useful in the workup of monocular diplopia.

Corneal Topography↗

Use of Verisyse iris-supported phakic intraocular lens for myopia in keratoconic patients.

We report 2 patients with stable keratoconus and high myopia who benefited from implantation of an iris-supported phakic intraocular lens (Verisyse, AMO) for correction of their refractive error. Both patients had a postoperative uncorrected visual acuity of 20/40. Endothelial cell density showed at most a 4% decrease, and no evidence of keratoconus progression was witnessed. The use of the Verisyse lens may be beneficial for certain keratoconic patients as an alternative step between rigid gas-permeable lenses and penetrating keratoplasty.

Corneal Topography↗