PubMed Health⌕ Search

PubMed · 15534821

MCG to ECG source differences: measurements and a two-dimensional computer model study.

Abstract

In this work we combine body surface potential map (BSPM) and magnetocardiogram (MCG) measurements with computer simulations in order to elucidate a recent thesis that claims the orthogonality of the main sources of MCG and ECG. Body surface currents and MCG pseudo currents are calculated from measured BSPM and MCG data, respectively. In contrast to the MCG-ECG source orthogonality thesis, we observe the main orientation of the BSPM currents and MCG pseudo currents to have similar axis during most of the depolarization R wave. In an attempt to explain such measurements we simulate a 2D transmural slice of the left ventricle in contact to a volume conductor. The main magnetic source currents along the wave front are indeed orthogonal to the extracellular electric current. However, fiber orientation inhomogeneity through the ventricular wall, volume conductor interface, wave front shape and extra- and intracellular potential distributions, all distort the symmetry of the current loops that contain the wave front currents. The resulting asymmetry rotates the main axis of the pseudo MCG currents away from the orthogonal axis of the body surface currents. Thus, the simulation results could solve the apparent contradiction between the orthogonal source theory and the observed similar ECG and MCG main current axis.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Rodrigo Weber Dos Santos, Olaf Kosch, Uwe Steinhoff, Steffen Bauer, Lutz Trahms, Hans Koch. 2004. MCG to ECG source differences: measurements and a two-dimensional computer model study.. https://doi.org/10.1016/j.jelectrocard.2004.08.036

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Case report: Symptoms of advanced heart failure--a case for radiofrequency catheter ablation?

A sixty-year-old man with previous history of coronary artery disease was admitted due to progressive worsening of dyspnoea at exertion (NYHA III functional class) and no angina. Coronary angiography confirmed occlusion of the right coronary artery which was naturally bypassed by homocollaterals with TIMI 3 flow to the peripheral branches. The lesion was not technically suitable for percutaneous angioplasty. The left coronary artery was without stenosis. On echocardiography, both the left ventricle and the left atrium were dilated and hemodynamically significant mitral regurgitation was present. Surface ECG showed a left bundle branch block with repeated runs of monomorphic ventricular ectopic beats (PVC). Radiofrequency catheter ablation of the focus in the posteroseptal region of the left ventricle underneath the mitral valve was performed using electroanatomical mapping system. After the procedure, mitral regurgitation decreased and reverse remodeling of the left ventricle and the left atrium occurred with concomitant significant clinical improvement of the patient. The authors discuss several treatment strategies: mitral valve repair surgery combined with revascularization, implantation of a biventricular ICD system or elimination of the focus of monomorphic VT runs by radiofrequency catheter ablation as a possible causal approach in the treatment of PVC-induced cardiomyopathy.

Body Surface Potential Mapping↗