PubMed Health⌕ Search

PubMed · 15534838

Tracking repolarization dynamics in real-life data.

Abstract

Ambulatory (Holter) electrocardiographic recordings provide the tools for tracking temporal instabilities of repolarization during various daily activities. However, analysis of low-amplitude repolarization changes in this setting is challenging due to the presence of multiple artifacts, variable activity levels, and other uncontrolled factors. Here we compare performance of different methods for continuous analysis of repolarization dynamics using simulated signals and real-life Holter recordings. Selection of relatively stable segments with a low baseline drift and accurate correction of baseline wander constitute the first step in repolarization analysis. We describe application of adaptive filtering, which yields more accurate results than non-adaptive techniques. Because small (microvolt-level) residual baseline drifts can be a source of error in tracking repolarization changes, stability of isoelectrical segment has to be controlled. To compare robustness of spectral and time-domain techniques for tracking temporal repolarization instabilities (T-wave alternans, TWA), we used simulated signals with changing heart rate, variable levels of TWA, noise, phase shifts, spurious artifacts, and period-four oscillations. In addition, we compared performances of the inter-beat and intra-beat averaging techniques for tracking dynamics of T-wave alternans. Using the simulated signals and real-life Holter data, we showed that analysis of information both in time and frequency domains combined with control of baseline drifts (surrogate analysis) gives a more reliable estimate of the low-amplitude repolarization dynamics than each of these techniques alone. To summarize, dynamic tracking of low-amplitude repolarization changes in ambulatory recordings is possible during most of the recording time but requires accurate control of baseline wander and stability of isoelectrical segments. Analysis of time-frequency distributions embedded in repolarization dynamics facilitates detection of abrupt and transient repolarization instabilities, including changes in the level of T-wave alternans and slower periodicities.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Vladimir Shusterman, Anna Goldberg. 2004. Tracking repolarization dynamics in real-life data.. https://doi.org/10.1016/j.jelectrocard.2004.08.054

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Striping artifact removal in VisiumHD data through nuclear counts modeling.

MOTIVATION: 10x Genomics VisiumHD enables spatial transcriptomics at 2 µm × 2 µm resolution but exhibits slide-specific, non-periodic striping artifacts due to lane-width variability. These multiplicative row/column effects distort bin total counts and can bias downstream analyses. The state-of-the-art destriping approach is the normalization procedure used as a preprocessing step in bin2cell; it applies sequential high-quantile row- then column-wise normalization, which is asymmetric and can introduce edge effects/macro-stripes and distortions of large-scale total-count structure. RESULTS: We propose a statistical destriping approach that leverages nuclei segmentation from the co-registered H&E image. Assuming transcript abundance is constant within each nucleus, we model bin counts with a negative binomial distribution whose mean is a product of a nucleus-specific concentration and row- and column-specific stripe-factors reflecting lane-width variation. We fit all parameters in a generalized linear modeling framework with cross-validated regularization on stripe-factors and iterative dispersion estimation, and use the fitted parameters to correct the observed counts into a destriped image. On synthetic data with known ground truth, our method improves stripe-factor estimation accuracy and reduces error in corrected counts relative to bin2cell and bin2cell-derived baselines. Across four public VisiumHD slides, it consistently lowers striping intensity while substantially better preserving biological signal present in the large-scale global count structure and avoiding the artifacts introduced by other methods. AVAILABILITY AND IMPLEMENTATION: All source code and links to publicly available data used for this study are available at https://github.com/paolamalsot/destriping-GLM.

Artifacts↗

ROC study of four LCD displays under typical medical center lighting conditions.

Nine observers reviewed a previously assembled library of 320 chest computed radiography (CR) images. Observers participated in four sessions, reading a different 1/4 of the sample on each of four liquid crystal displays: a 2-megapixel (MP) consumer color display, a 2-MP business color display, a 2-MP medical-grade gray display, and a 3-MP gray display. Each display was calibrated according to the DICOM Part 14 standard. The viewing application required observer log-in, then randomized the order of the subsample seen on the display, and timed the responses of the observer to render a 1-5 judgment on the absence or presence of ILD on chest CRs. Selections of 1-2 were considered negative, 3 was indeterminate, and 4-5 were positive. The order of viewing sessions was also randomized for each observer. The experiment was conducted under controlled lighting, temperature, and sound conditions to mimic conditions typically found in a patient examination room. Lighting was indirect, and illuminance at the display face was 195 +/- 8% lux and was monitored over the course of the experiment. The average observer sensitivity for the 2 MP color consumer, 2 MP business color, 2 MP gray, and 3 MP gray displays were 83.7%, 84.1%, 85.5%, and 86.7%, respectively. The only pairwise significant difference was between the 2-MP consumer color and the 2-MP gray (P = 0.05). Effect of order within a session was not significant (P = 0.21): period 1 (84.3%), period 2 (86.2%), period 3 (85.4%), period 4 (84.1%). Observer specificity for the various displays was not statistically significant (P = 0.21). Finally, a timing analysis showed no significant difference between the displays for the user group (P = 0.13), ranging from 5.3 s (2 MP color business) to 5.9 s (3 MP Gray). There was, however, a reduction in time over the study that was significant (P < 0.001) for all users; the group average decreased from 6.5 to 4.7 s per image. Physical measurements of the resolution, contrast, and noise properties of the displays were acquired. Most notably, the noise of the displays varied by 3.5x between the lowest and highest noise displays. Differences in display noise were indicative of observer performance. However, the large difference in the magnitude of the noise was not predictive of the small difference (3%) in the observer sensitivity for various displays. This is likely because detection of interstitial lung disease is limited by "anatomical noise" rather than display or x-ray image noise.

Artifacts↗

The effect of smoking on DNA effects in the comet assay: a meta-analysis.

The comet assay (alkaline single-cell gel electrophoresis, SCG or SCGE) is frequently used in biomonitoring to detect genotoxic effects in humans exposed at the workplace or in their environment. Because of its ready accessibility, blood is most frequently used in such studies. Many studies investigated cigarette smoking either as a genotoxic exposure itself or as a potential confounding factor in occupational studies. However, although smoking is considered to be a relevant exposure towards various genotoxins, conflicting results have been reported in the comet assay studies. The actual reasons for this discrepancy are not known. To further evaluate evidence for smoking-related DNA effects in the comet assay, we now used a meta-analysis approach based on a literature search. We identified 38 studies from 37 publications which were suited for a formal meta-analysis based on the standardized mean difference (SMD) between the study groups. The evaluation of these 38 studies indicated higher levels of DNA damage in smokers than in non-smokers [under a random effects model, SMD = 0.55, 95% confidence interval = (0.16-0.93)]. Subdividing these studies into studies investigating the effect of smoking as a genotoxic exposure (Type A studies, n = 12) and studies investigating smoking as a potential confounder in occupational studies (Type B, n = 26) indicated a significant difference only in Type A studies but not in Type B studies. Furthermore, studies using image analysis or image length measurements (n = 23) only indicated a tendency for a genotoxic effect of smoking, whereas studies using an arbitrary score (n = 15) found a significantly higher level of DNA damage in smokers.

Artifacts↗