Force matching errors following eccentric exercise.

Abstract

During eccentric exercise contracting muscles are forcibly lengthened, to act as a brake to control motion of the body. A consequence of eccentric exercise is damage to muscle fibres. It has been reported that following the damage there is disturbance to proprioception, in particular, the senses of force and limb position. Force sense was tested in an isometric force-matching task using the elbow flexor muscles of both arms before and after the muscles in one arm had performed 50 eccentric contractions at a strength of 30% of a maximum voluntary contraction (MVC). The exercise led to an immediate reduction of about 40%, in the force generated during an MVC followed by a slow recovery over the next four days, and to the development of delayed onset muscle soreness (DOMS) lasting about the same time. After the exercise, even though participants believed they were making an accurate match, they made large matching errors, in a direction where the exercised arm developed less force than the unexercised arm. This was true whichever arm was used to generate the reference forces, which were in a range of 5-30% of the reference arm's MVC, with visual feedback of the reference arm's force levels provided to the participant. The errors were correlated with the fall in MVC following the exercise, suggesting that participants were not matching force, but the subjective effort needed to generate the force: the same effort producing less force in a muscle weakened by eccentric exercise. The errors were, however, larger than predicted from the measured reduction in MVC, suggesting that factors other than effort might also be contributing. One factor may be DOMS. To test this idea, force matches were done in the presence of pain, induced in unexercised muscles by injection of hypertonic (5%) saline or by the application of noxious heat to the skin over the muscle. Both procedures led to errors in the same direction as those seen after eccentric exercise.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

U Proske, J E Gregory, D L Morgan, P Percival, N S Weerakkody, B J Canny. 2004. Force matching errors following eccentric exercise.. https://doi.org/10.1016/j.humov.2004.08.012

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Modulation operated by the sympathetic nervous system on jaw reflexes and masticatory movement.

The sympathetic nervous system (SNS), that is activated under condition of physical, psychological and psychosocial stress, affects force production and fatigability of muscles by controlling both muscle blood flow and the intracellular contractile mechanism. In addition SNS may affect motor function by modulating afferent activity from muscle spindles that are highly concentrated in jaw-closing muscles. Possible implications of these actions on masticatory function and myofascial pain are discussed.

Electromyography↗

Abnormal responses to repetitive transcranial magnetic stimulation in multiple system atrophy.

We studied the response of the motor cortex to brief trains of suprathreshold repetitive transcranial magnetic stimulations (rTMS) in patients with the Parkinson-variant of multiple system atrophy (MSA-P) and compared it to patients with idiopathic Parkinson's disease (PD) and healthy controls. Eight subjects were studied in each group, and patients were matched for disease severity as assessed by Hoehn & Yahr stages. rTMS was delivered at rest and during low-level contractions in trains of 10 stimulations at 5 Hz, and stimulation intensity was set to result in an motor evoked potential (MEP) in the first dorsal interosseus muscle of 0.5 to 1.0 mV. In MSA-P, MEP amplitude at rest was already reduced after the second stimulus and remained so, while it did not change in PD and controls. During contraction, MEP size did not change during the train in any group. The silent period that followed the last stimulus was of similar duration as the first stimulus in MSA-P, but was increased in PD and controls. These findings indicate that abnormal inhibition occurs within the motor cortex in MSA-P, despite dopaminergic treatment and indicate differences in cortical dysfunction between MSA-P and PD. We suggest that these abnormalities reflect the motor cortex pathology found in MSA-P.

Electromyography↗