PubMed Health⌕ Search

PubMed · 15561318

Reversible myocardial dysfunction: basics and evaluation.

Abstract

Large areas of non-functional but viable myocardium with reversible dysfunction are commonly seen in patients with acute myocardial infarction. Both reperfusion of acutely ischemic myocardium and chronic myocardial ischemia may produce a reversible forms of ventricular dysfunction. The two main conditions that lead to reversible myocardial dysfunction are stunned myocardium and hibernating myocardium. Myocardial stunning represents post-ischemic myocardial dysfunction that persists despite restoration of normal flow, with gradual return of contractile function. Hibernating myocardium is a state of persistently impaired myocardial function at rest due to reduced coronary blood flow owing to residual stenosis that can be restored toward normal by revascularization. The success of the revascularization procedures depends on the presence of amount of dysfunctional but viable myocardium. The basics and evaluation of reversible myocardial dysfunction are reviewed.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Ramesh M Gowda, Ijaz A Khan, Balendu C Vasavada, Terrence J Sacchi. 2004. Reversible myocardial dysfunction: basics and evaluation.. https://doi.org/10.1016/j.ijcard.2003.08.023

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

ACCF/ASNC appropriateness criteria for single-photon emission computed tomography myocardial perfusion imaging (SPECT MPI): a report of the American College of Cardiology Foundation Quality Strategic Directions Committee Appropriateness Criteria Working Group and the American Society of Nuclear Cardiology endorsed by the American Heart Association.

Under the auspices of the American College of Cardiology Foundation (ACCF) and the American Society of Nuclear Cardiology (ASNC), an appropriateness review was conducted for radionuclide cardiovascular imaging (RNI), specifically gated single-photon emission computed tomography myocardial perfusion imaging (SPECT MPI). The review assessed the risks and benefits of the imaging test for several indications or clinical scenarios and scored them based on a scale of 1 to 9, where the upper range (7 to 9) implies that the test is generally acceptable and is a reasonable approach, and the lower range (1 to 3) implies that the test is generally not acceptable and is not a reasonable approach. The mid range (4 to 6) implies that the test may be generally acceptable and may be a reasonable approach for the indication. The indications for this review were primarily drawn from existing clinical practice guidelines and modified based on discussion by the ACCF Appropriateness Criteria Working Group and the Technical Panel members who rated the indications. The method for this review was based on the RAND/UCLA approach for evaluating appropriateness, which blends scientific evidence and practice experience. A modified Delphi technique was used to obtain first- and second-round ratings of 52 clinical indications. The ratings were done by a Technical Panel with diverse membership, including nuclear cardiologists, referring physicians (including an echocardiographer), health services researchers, and a payer (chief medical officer). These results are expected to have a significant impact on physician decision making and performance, reimbursement policy, and future research directions. Periodic assessment and updating of criteria will be undertaken as needed.

Coronary Circulation↗

Comparison of treadmill exercise versus dipyridamole stress with myocardial perfusion imaging using rubidium-82 positron emission tomography.

OBJECTIVES: This study assessed the feasibility of treadmill exercise rubidium-82 ((82)Rb) positron emission tomography (PET) and compared image quality and diagnostic content with dipyridamole (82)Rb PET in patients referred for evaluation of coronary artery disease (CAD). BACKGROUND: Dipyridamole stress (82)Rb PET myocardial perfusion imaging (MPI) is an accurate imaging modality used to diagnose CAD and determine prognosis. Although pharmacologic stress is used routinely, exercise treadmill stress may be an alternative and provide clinical information helpful to decision making, particularly for patients unwilling or unable to tolerate pharmacologic stress. METHODS: Fifty patients (mean age, 60 +/- 10 years; 47 men) underwent treadmill exercise and dipyridamole (82)Rb PET. Images were assessed: 1) qualitatively using a 17-segment model and a semiquantitative visual score on a five-point scale and with calculation of summed stress score (SSS), summed rest score (SRS), and summed difference score (SDS); and 2) quantitatively with a 70% threshold for abnormal perfusion and expressed as extent of abnormal perfusion (% left ventricular). RESULTS: Treadmill exercise was preferred by 74% of patients (37 of 50, p < 0.001). The exercise and dipyridamole (82)Rb PET summed scores and quantitative extent of abnormal perfusion were very similar and highly correlated. Results of Bland-Altman analysis showed no significant bias. Image quality was superior with exercise stress with greater myocardial uptake and higher target to background ratios. CONCLUSIONS: Treadmill exercise (82)Rb PET is feasible and provides imaging results of similar diagnostic content and superior image quality compared with dipyridamole stress. Treadmill exercise is a reasonable alternative to pharmacologic stress with (82)Rb PET MPI.

Coronary Circulation↗