PubMed Health⌕ Search

PubMed · 15565692

Peak compression and resolution for electrophoretic separations in diverging microchannels.

Abstract

We report the results of experiments and simulations on electrokinetic flow in diverging microchannels (with cross-sectional area that increases with distance along the channel). Because of conservation of mass and charge, the velocity of an analyte in the channel decreases as the channel cross-section increases. Consequently, the leading edge of a band of sample moves more slowly than the trailing edge and the sample band is compressed. Sample peak widths, rather than increasing diffusively with time, can then be controlled by the geometry of the channel and can even be made to decrease with time. We consider the possibility of using this peak compression effect to improve the resolution of electrophoretic separations. Our results indicate that for typical separations that are dispersion limited, this peak compression effect is more than offset by the decreased distance between peaks, and the separation resolution in diverging channels is worse than that found for straight channels at the same applied voltage. For separations in very short channels or at very high field strengths, however, when the separation efficiency is injection limited, the peak compression effect is dominant and diverging channels can then be used to achieve improved separation resolution.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

David Ross, Cornelius F Ivory, Laurie E Locascio, Kevin E Van Cott. 2004. Peak compression and resolution for electrophoretic separations in diverging microchannels.. https://doi.org/10.1002/elps.200406119

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Ultrasonic standing wave manipulation technology integrated into a dielectrophoretic chip.

Several cell-based biological applications in microfluidic systems require simultaneous high-throughput and individual handling of cells or other bioparticles. Available chip-based tools for contactless manipulation are designed for either high-precision handling of individual particles, or high-throughput handling of ensembles of particles. In order to simultaneously perform both, we have combined two manipulation technologies based on ultrasonic standing waves (USWs) and dielectrophoresis (DEP) in a microfluidic chip. The principle is based on the competition between long-range ultrasonic forces, short-range dielectrophoretic forces and viscous drag forces from the fluid flow. The ultrasound is coupled into the microchannel resonator by an external transducer with a refractive element placed on top of the chip, thereby allowing transmission light microscopy to continuously monitor the biological process. The DEP manipulation is generated by an electric field between co-planar microelectrodes placed on the bottom surface of the fluid channel. We demonstrate flexible and gentle elementary manipulation functions by the use of USWs and linear or curved DEP deflector elements that can be used in high-throughput biotechnology applications of individual cells.

Electrophoresis, Microchip↗

Rapid on-column analysis of glucosamine and its mutarotation by microchip capillary electrophoresis.

A novel electrophoretic microchip method for analyzing alpha- and beta-d-glucosamine and their interconversion in solution is presented. d-Glucosamine is labeled with fluorescamine and analyzed by capillary electrophoresis in under 2 min revealing its pH-dependent mutarotation between the alpha- and beta-anomers. The forward interconversion rates for the labeled sugars, based on an iterative analysis of the plateau heights between the peaks, are 0.72+/-0.09, 1.3+/-0.1, and 2.2+/-0.3 x 10(-3)s(-1) at pH 8.99, 9.51 and 10.01, respectively. In a separate experiment, the mutarotation of the unlabeled alpha-d-anomer was followed; the relative intensities of the alpha- and beta-peaks as a function of reaction time at pH 9.51 give a forward rate constant of 0.6+/-0.1 x 10(-3)s(-1). These results demonstrate that fast microchip separations, previously exploited for amine, amino acid, and nucleobase analysis, can also be used to analyze amino sugars and their mutarotation.

Electrophoresis, Microchip↗

Dielectrophoresis field flow fractionation of single-walled carbon nanotubes.

We report a study on Dielectrophoresis Field Flow Fractionation of Single-Wall Carbon Nanotubes (SWNTs). SWNTs, individually suspended in 1% SDBS solution, were separated by type when they passed a dielectrophoresis field flow fractionation device where 1 MHz AC voltage was supplied and the field strength was well below 1 V per mum. Furthermore, we uniquely observed enrichment of semiconductive SWNTs based on their band gap. In addition to Raman spectrum, UV-vis absorption and NIR fluorescence spectra were used for solution samples for characterization.

Electrophoresis, Microchip↗