PubMed Health⌕ Search

PubMed · 15580587

Continuous perfusion microfluidic cell culture array for high-throughput cell-based assays.

Abstract

We present for the first time a microfluidic cell culture array for long-term cellular monitoring. The 10 x 10 array could potentially assay 100 different cell-based experiments in parallel. The device was designed to integrate the processes used in typical cell culture experiments on a single self-contained microfluidic system. Major functions include repeated cell growth/passage cycles, reagent introduction, and real-time optical analysis. The single unit of the array consists of a circular microfluidic chamber, multiple narrow perfusion channels surrounding the main chamber, and four ports for fluidic access. Human carcinoma (HeLa) cells were cultured inside the device with continuous perfusion of medium at 37 degrees C. The observed doubling time was 1.4 +/- 0.1 days with a peak cell density of approximately 2.5*10(5) cells/cm(2). Cell assay was demonstrated by monitoring the fluorescence localization of calcein AM from 1 min to 10 days after reagent introduction. Confluent cell cultures were passaged within the microfluidic chambers using trypsin and successfully regrown, suggesting a stable culture environment suitable for continuous operation. The cell culture array could offer a platform for a wide range of assays with applications in drug screening, bioinformatics, and quantitative cell biology.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Paul J Hung, Philip J Lee, Poorya Sabounchi, Robert Lin, Luke P Lee. 2005-01-05. Continuous perfusion microfluidic cell culture array for high-throughput cell-based assays.. https://doi.org/10.1002/bit.20289

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Quantitation of interaction of lipids with polymer surfaces in cell culture.

As cell culture medium development efforts have progressed towards leaner, serum-free, and chemically defined formulations, it has become increasingly important to ensure that the appropriate concentrations of all nutrients are maintained and delivered at point of use. In light of concurrent efforts to progress to disposable polymeric storage and culture platforms, the characterization and control of medium component interactions with container surfaces can be a key issue in ensuring consistent delivery of these medium formulations. These studies characterize the interactions of lipids with culture surfaces typically encountered in the bioprocess industry using model systems. The extent and kinetics of lipid association with polymeric surfaces were determined using radio-labeled linoleic acid and cholesterol. The effect of methyl-beta-cyclodextrin, a component commonly used to solubilize lipids in culture media, on association kinetics was also examined. In addition, loss of lipids across a sterilizing membrane filter was quantified. We find that there is potential for significant loss of hydrophobic components due to non-specific binding to surfaces at timescales relevant to a typical cell culture process. The extent of loss is dependent on the nature of the hydrophobic component as well as the type of surface. These studies highlight the potential of the extracellular environment to modify medium composition and also emphasize the importance of medium formulation strategies, including those used in the delivery of hydrophobic components. It is noted, however, that the level of loss is very dependent on the specific system including the composition of the culture medium used.

Cell Culture Techniques↗

Growing tissue-like constructs with Hep3B/HepG2 liver cells on PHBV microspheres of different sizes.

In this study, an oil-in-water emulsion solvent evaporation technique was used to fabricate poly(3-hydroxybutyrate-co-3-hydroxyvalerate) (PHBV, 8% PHV), microspheres as scaffold, to guide liver cell growth. Human hepatoma cell lines, HepG2 and Hep3B, were cultured in vitro on both the microspheres and polymer films. SEM and optical microscope images showed that multilayer cells were formed among the microspheres to bridge them together and developed into cell-construct aggregates after 1 week of culture. MTT results showed that the cell proliferation on the microspheres was more than two times higher than that on the films after 12 days of culture. The cells seeded on microspheres secreted albumin 2-4 times more than that on the positive control after 1 week of culture, which indicated that this hepatic function was greatly improved by the aggregation of cells on microspheres. Although HepG2 failed to express P-450 activity, this hepatic function was preserved when Hep3B cultured on microspheres. All the results indicated that PHBV microspheres are appropriate scaffolds for liver tissue engineering.

Cell Culture Techniques↗

Three-dimensional numerical modeling and computational fluid dynamics simulations to analyze and improve oxygen availability in the AMC bioartificial liver.

A numerical model to investigate fluid flow and oxygen (O(2)) transport and consumption in the AMC-Bioartificial Liver (AMC-BAL) was developed and applied to two representative micro models of the AMC-BAL with two different gas capillary patterns, each combined with two proposed hepatocyte distributions. Parameter studies were performed on each configuration to gain insight in fluid flow, shear stress distribution and oxygen availability in the AMC-BAL. We assessed the function of the internal oxygenator, the effect of changes in hepatocyte oxygen consumption parameters in time and the effect of the change from an experimental to a clinical setting. In addition, different methodologies were studied to improve cellular oxygen availability, i.e. external oxygenation of culture medium, culture medium flow rate, culture gas oxygen content (pO(2)) and the number of oxygenation capillaries. Standard operating conditions did not adequately provide all hepatocytes in the AMC-BAL with sufficient oxygen to maintain O(2) consumption at minimally 90% of maximal uptake rate. Cellular oxygen availability was optimized by increasing the number of gas capillaries and pO(2) of the oxygenation gas by a factor two. Pressure drop over the AMC-BAL and maximal shear stresses were low and not considered to be harmful. This information can be used to increase cellular efficiency and may ultimately lead to a more productive AMC-BAL.

Cell Culture Techniques↗