Linear accelerator output variability.

Abstract

The Wellington Cancer Centre is equipped with two matched linear accelerators (Varian 2100CD) linear accelerators (identified as SN1027 and SN42). Each morning, before treatments commence, a radiation therapist carries out an output constancy check of the radiation output and every fortnight a physicist measures, in a phantom, the delivered radiation dose to check on the machine calibration. The daily output checks have been recorded into a database (Argus QA for Radiation Oncology) since August 1997 and in June 1998 the fortnightly calibration measurements were added. The information in the database, up to April 2003, has been analysed to consider the quality of the daily constancy checks as compared with the fortnightly calibration measurements and whether the data contains useful information on machine performance. After allowance for the effects of machine recalibration the fortnightly calibration measurements had an average standard deviation of 0.4% and the daily constancy checks 0.8%. The daily constancy checks had a greater number of large deviations than would be expected assuming a normal distribution and were not a good predictor of the need for a recalibration. The fortnightly calibration measurements with a much lower spread give a reliable indication of the need for a recalibration allowing the adoption of a +/- 1% tolerance. Over the period analysed one accelerator (SN42) was relatively stable with the output generally drifting between +/- 1% while the other (SN1027) had a consistent increase in the average output of about 2.5% per year.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

I A Luketina, L Greig. 2004. Linear accelerator output variability.. https://doi.org/10.1007/bf03178676

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Discrimination of normal, inflammatory, premalignant, and malignant oral tissue: a Raman spectroscopy study.

Optical spectroscopy methods are fast emerging as potential alternatives for early diagnosis of cancer. A Raman spectroscopy method for discrimination of normal and malignant oral tissues has been developed by us earlier. It is necessary to evaluate and establish the validity of the approach before it can be routinely used. In the present study, our Raman spectroscopy investigations are extended further to evaluate the efficacy of the technique to discriminate between normal, inflammatory, premalignant, and malignant conditions in oral tissue. Spectral profiles of normal, malignant, premalignant, and inflammatory conditions show pronounced differences between one another. Spectra of normal tissues can be attributed mainly to lipids whereas pathological tissue spectra are dominated by proteins. Principal components analysis (PCA) of the spectral data sets belonging to the four different categories showed that scores of factors differentiated between normal and all pathological conditions but gave only poor discrimination among the three pathological states. PCA combined with multiparameter limit tests allow match/mismatch criteria to be applied to test samples when pathologically certified calibration sets are available in each class. It is shown that by this method all the four tissue types could be discriminated and diagnosed correctly. The biochemical differences between normal and pathological conditions of oral tissue are also discussed from spectral differences of the different classes of spectra.

Calibration↗

Determination of rizatriptan in human plasma by liquid chromatographic-eletrospray tandem mass spectrometry: application to a pharmacokinetic study.

A sensitive liquid chromatographic-tandem mass spectrometry(LC-MS/MS) method was developed for the determination of rizatriptan in human plasma. The analytes were extracted from plasma samples by liquid-liquid extraction, separated on a Zorbax XDB C8 column (150 x 4.6 mm i.d.) and detected by tandem mass spectrometry with an electrospray ionization interface. Zomitriptan was used as the internal standard. The method had a lower limit of quantitation of 50 pg/mL for rizatriptan, which showed more sensitivity and speed of analysis compared with reported methods. The within- and between-day precision was measured to be below 11.71% and accuracy between -5.87 and 0.86% for all quality control samples. This quantitation method was successfully applied to the evaluation of the pharmacokinetic profiles of rizatriptan after single oral administration of 5, 10 and 15 mg rizatriptan tablets to 10 healthy volunteers (five males and five females).

Calibration↗