For high throughput proteome analysis of highly complex protein mixtures, we have constructed a fully automated online system for multi-dimensional protein profiling, which utilizes a combination of two-dimensional liquid chromatography and tandem mass spectrometry (2D-LC-MS-MS), based on our well-established offline system described previously [K. Fujii, T. Nakano, T. Kawamura, F. Usui, Y. Bando, R. Wang, T. Nishimura, J. Proteome Res. 3 (2004) 712]. A two-valve switching system on a programmable auto sample injector is utilized for online two-dimensional chromatography with strong cation-exchange (SCX) and reversed-phase (RP) separations. The SCX separation is carried out during the equilibration of RP chromatography and the entire sequence of analysis was performed under fully automated conditions within 4 h, based on six SCX fractionations, and 40 min running time for the two-dimensional RP chromatography. In order to evaluate its performance in the detection and identification of proteins, digests of six standard proteins and yeast 20S proteasome have been analyzed and their results were compared to those obtained by the one-dimensional reversed-phase chromatography system (ID-LC-MS-MS). The 2D-LC-MS-MS system demonstrated that both the number of peptide fragments detected and the protein coverage had more than doubled. Furthermore, this multi-dimensional protein profiling system was also applied to the human 26S proteasome, which is one of the highly complex protein mixtures. Consequently, 723 peptide fragments were identified as 31 proteasome components, together with other coexisting proteins in the sample. The identification could be comprehensively performed with a 63% sequence coverage on an average, and additionally, with modifications at the N-terminus. These results indicated that the online 2D-LC-MS-MS system being described here is capable of analyzing highly complex protein mixtures in a high throughput manner, and that it would be applicable to dynamic proteomics.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Kiyonaga Fujii, Tomoyo Nakano, Hiroshi Hike, Fumihiko Usui, Yasuhiko Bando, Hiromasa Tojo, Toshihide Nishimura. 2004-11-19. Fully automated online multi-dimensional protein profiling system for complex mixtures.. https://doi.org/10.1016/j.chroma.2004.09.078

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Characteristics of the m2000 automated sample preparation and multiplex real-time PCR system for detection of Chlamydia trachomatis and Neisseria gonorrhoeae.

We evaluated a new real-time PCR-based prototype assay for the detection of Chlamydia trachomatis and Neisseria gonorrhoeae developed by Abbott Molecular Inc. This assay is designed to be performed on an Abbott m2000 real-time instrument system, which consists of an m2000sp instrument for sample preparation and an m2000rt instrument for real-time PCR amplification and detection. The limit of detection of this prototype assay was determined to be 20 copies of target DNA for both C. trachomatis and N. gonorrhoeae, using serially diluted linearized plasmids. No cross-reactivity could be detected when 55 nongonococcal Neisseria isolates and 3 non-C. trachomatis Chlamydia isolates were tested at 1 million genome equivalents per reaction. Concordance with the Roche Amplicor, BDProbeTec ET, and Gen-Probe APTIMA Combo 2 tests was assessed using unlinked/deidentified surplus clinical specimens previously analyzed with these tests. For C. trachomatis, concordance for positive results ranged from 93.7% to 100%, while concordance for negative results ranged from 98.2% to 100%. For N. gonorrhoeae, concordance for positive and negative results ranged from 91.4% to 100% and 99.3% to 100%, respectively. A workflow analysis of the prototype assay was conducted to obtain information on throughput under laboratory conditions. At 48 samples/run, the time to first result for both C. trachomatis and N. gonorrhoeae was 4.5 h. A total of 135 patient specimens could be analyzed in 8.9 h, with 75 min of hands-on time. This study demonstrated the technical and clinical feasibility of the new Abbott real-time PCR C. trachomatis/N. gonorrhoeae assay.

Automation↗

Pronase-immobilized enzyme reactor: an approach for automation in glycoprotein analysis by LC/LC-ESI/MSn.

An automated analytical approach is proposed for simultaneous characterization of glycan and peptide moieties in pronase-generated glycopeptides. The proposed method is based on the use of a new pronase-immobilized enzyme reactor for the on-line rapid digestion of the target glycoprotein. By coupling the bioreactor to a Hypercarb chromatographic trap column, on-line selective glycopeptide enrichment prior to normal-phase liquid chromatography-mass spectrometry was obtained. A detailed study was carried out for integration and automation of each phase of the proposed analytical procedure. On-line digestion allowed extensive cleavage of the model protein (ribonuclease B), yielding to glycopeptides with peptide moieties up to eight amino acids, carrying the Man5-Man9 N-glycans each, selectively resolved on an Amide-80 column. The use of a linear ion trap instrument resulted in efficient ion capture and led to MS3 acquisition times and spectra quality similar to those for MS2, allowing the unambiguous identification of glycan (MS2) and peptide (MS3) sequences. The proposed procedure reduces the glycoprotein analysis time from approximately 3 days, as in most of the traditional off-line methods, to approximately 1 h.

Automation↗

An improved high-throughput liquid chromatographic/tandem mass spectrometric method for terbinafine quantification in human plasma, using automated liquid-liquid extraction based on 96-well format plates.

A fully automated high-throughput liquid chromatography/tandem mass spectrometry (LC-MS/MS) method was developed for terbinafine quantification in human plasma. The plasma samples were treated by liquid-liquid extraction (LLE) in 2.2 mL 96-deepwell plates. Terbinafine and the internal standard (IS) N-methyl-1-naphthalenemethylamine were extracted from human plasma by LLE, using a mixture of methyl t-butyl ether (MTBE)-hexane (70:30, v/v) as the organic solvent. All liquid transfer steps, including preparation of calibration standards and quality control samples, as well as the addition of the IS, were performed automatically by using robotic liquid handling workstations. After vortexing, centrifugation and freezing, the supernatant organic solvent was evaporated and reconstituted in a small volume of a reconstitution solution. Sample analysis was performed by reversed-phase LC-MS/MS, with positive ion electrospray ionization, using multiple reaction monitoring (MRM). The method had a very short sample preparation time and a chromatographic run time of 2.2 min. It was proved to have excellent sensitivity, specificity, accuracy as well as inter- and intraday precision for the quantification of terbinafine in human plasma. The calibration curve was linear for the range of concentrations 5.0-2000.0 ng/mL. The proposed method was applied to the rapid and reliable determination of terbinafine in a bioequivalence study after per os administration of 250 mg tablet formulations of terbinafine.

Automation↗