Sensitive method for the determination of roxarsone using solid-phase microextraction with multi-detector gas chromatography.

Abstract

We describe the development, optimization, and application of a novel method for the unequivocal identification and quantification of roxarsone (3-nitro-4-hydroxyphenylarsonic acid, 3-NHPAA) at low microg L(-1) levels. The method is based on capillary gas-liquid chromatography with parallel quadrupole ion-trap mass spectrometric (QIT-MS) and pulsed flame photometric detection (PFPD). The sensitive method couples the arsenic specificity of PFPD with the high selectivity of molecular MS for the determination of roxarsone, dimethylarsenic acid (DMAA), and monomethylarsonic acid (MMAA) in complex matrices. Analytes were derivatized based on the approach we previously reported [B. Szostek, J.H. Aldstadt, J. Chromatogr. A 807 (1998) 253 and D.R. Killelea, J.H. Aldstadt, J. Chromatogr. A 918 (2001) 169] for the reaction of organoarsenicals with 1,3-propanedithiol (PDT). The cyclic dithiaarsenolines formed were extracted from the sample matrix in the liquid phase by solid-phase microextraction (SPME). The optimized SPME conditions employed a 65 microm polydimethlysiloxane-divinylbenzene (PDMS-DVB) fiber, extraction temperature of 70 degrees C and fiber equilibration time of 15.0 min. The mass spectrum of the dithiaarsenoline of roxarsone showed a base peak that corresponded to the predicted structure at m/z 319 and the tell-tale peak of an arsenic compound derivatized with PDT at m/z 181. Further peaks at m/z 149 and 228 were observed and found to be unique to roxarsone, formed by an interesting internal rearrangement of the ONOH functionality. A linear calibration model was prepared for roxarsone over an environmentally relevant range (0.0-100 microg L(-1)) and a detection limit of 2.69 microg L(-1) (3sigma) was observed. The method was applied to several fortified environmental surface water samples (50 microg L(-1)) where the average recovery for roxarsone was 103+/-10.9%.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Aaron R Roerdink, Joseph H Aldstadt. 2004-11-19. Sensitive method for the determination of roxarsone using solid-phase microextraction with multi-detector gas chromatography.. https://doi.org/10.1016/j.chroma.2004.09.071

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Quantitative contrast-enhanced computed tomography: is there a need for system calibration?

The purpose of the study was to perform phantom studies to assess the impact of computed tomography (CT) system variability on quantitative measurements of contrast enhancement. A phantom containing tubes of contrast material at dilutions of 120, 1:35, 1:50, 1:100 and 1:200 arranged in air or water was imaged using 11 CT systems at 9 institutions. All systems had undergone routine calibration against air and water in accordance with the manufacturers' recommendations. For a given tube voltage, the relationship between the iodine concentration and CT attenuation value on a single system varied by 17 to 24% over 46-48 weeks. The coefficients of variance for iodine calibration factors across different CT systems were 8.9% in air and 5.1% in water. Calibration of individual CT systems for iodine response is required to allow comparison of quantitative measurements of contrast enhancement across different institutions. Using the iodine calibration factor to express contrast enhancement as iodine concentration would facilitate the universal application of diagnostic enhancement thresholds, especially if the necessary calculations were performed by software installed on the CT console.

Calibration↗

Fatty acids by high-performance liquid chromatography and evaporative light-scattering detector.

A high-performance liquid chromatographic (HPLC) separation method with an evaporative light-scattering detector (ELSD) has been developed for the separation and quantitative analysis of fatty acid methyl esters (FAME) in three different oils. Reverse-phased C18 HPLC separation of 13 FAME is achieved using a methanol/water eluent mixture. The retention times (RT) reflect the elution behavior of these compounds on C18 reversed-phase HPLC. The proposed method is tested on: soybean oil (Glycine max L.) as reference sample, rice bran oil (Oryza sativa L.), pumpkin seed oil (Cucurbita pepo L.) and algal oil (Arthrospira platensis Nordst.).

Calibration↗