Rapid sequential heart-cut multidimensional gas chromatographic analysis.

Abstract

A method is described which allows the sequential fast analysis of heart-cuts taken during the first column elution of an essential oil sample in a multidimensional gas chromatography experiment. In this investigation, a relatively short, narrow bore capillary column is used in the second dimension, with fast cryogenic modulation permitting rapid delivery of cryofocussed heart-cuts into the second column of the multidimensional arrangement. In this implementation, the total analysis time on the second column is of the order of 30 s, which is less than the duration of the sampled heart-cuts (1 min), with peak theoretical efficiencies of about 7000 m(-1). Thus, the method should allow on-line heart-cutting of as many discrete heart-cuts as one may require from the first dimension chromatogram, and so two-dimensional separation can be achieved for almost the whole sample in one single analysis without the need for repeat injections or cycling of the oven temperature. The method is demonstrated by the transfer and rapid re-injection of 1 min heart-cuts taken from an initial separation stage of peppermint essential oil. The cryofocussing and fast analysis step is shown to increase signal response by up to 40-fold. Total peak capacity in the described system is measured to be of the order of 1800, with capacities of about 20-30 for each 30 s second dimension analysis. By increasing the frequency of sampling to remove excessive (unused) time to develop the 2D separation, it should be possible to achieve peak capacities of 5000 or more baseline resolved peaks.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Michael Dunn, Robert Shellie, Paul Morrison, Philip Marriott. 2004-11-12. Rapid sequential heart-cut multidimensional gas chromatographic analysis.. https://doi.org/10.1016/j.chroma.2004.05.048

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Preparation of Fe3O4-C18 nano-magnetic composite materials and their cleanup properties for organophosphorous pesticides.

Magnetic Fe3O4-C18 composite nanoparticles of approximately 5-10 nm in size were synthesized and characterized by IR spectroscopy, atomic absorption spectroscopy, X-ray diffraction, and transmission electron microscopy. The magnetic Fe3O4-C18 composite nanoparticles were applied for cleanup and enrichment of organophosphorous pesticides. Comparative studies were carried out between magnetic Fe3O4-C18 composite nanoparticles and common C18 materials. Residues of organophosphorous pesticides were determined by gas chromatography in combination with a nitrogen/phosphorus detector. The cleanup and enrichment properties of magnetic Fe3O4-C18 composite nanoparticles are comparable with those of common C18 materials for enrichment of organophosphorous pesticides, but the cleanup and enrichment are faster and easier to perform.

Chromatography, Gas↗

Photoinduced generation of 2,3-butanedione from riboflavin.

The volatile compound formation from riboflavin solution of a phosphate buffer (0.1 M, pH 6.5) under light for 15 h was studied by SPME-GC and SPME-GC/MS analysis. Only one major compound in the riboflavin solution was formed and increased as the light exposure time increased. The light-exposed riboflavin solution had a buttery odor. The compound of riboflavin solution under light was analyzed by gas chromatography and olfactometry. The major volatile compound eluted from the gas chromatograph had a buttery odor. The buttery odor compound was positively identified as 2,3-butanedione by a combination of gas chromatographic retention time, mass spectrum, and odor evaluation of authentic 2,3-butanedione. The addition of sodium azide, a singlet oxygen quencher, to riboflavin solution minimized the formation of the buttery odor compound. Singlet oxygen was involved in the formation of the buttery odor. The 2,3-butanedione was produced from the reaction between riboflavin and singlet oxygen. Singlet oxygen was formed from triplet oxygen by riboflavin photosensitization mechanism. This is the first reported oxidation reaction between riboflavin and singlet or triplet in food and biological systems.

Chromatography, Gas↗

Multiresidue method for determination of 35 pesticides in virgin olive oil by using liquid-liquid extraction techniques coupled with solid-phase extraction clean up and gas chromatography with nitrogen phosphorus detection and electron capture detection.

A method for the multiresidue determination of 35 pesticides (30 insecticides and five herbicides) in olive oil by gas chromatography (GC) is described. Three liquid-liquid extraction (LLE) procedures based on (i) partition of pesticides between acetonitrile (ACN) and oil solution in n-hexane, (ii) partition of pesticides between saturated ACN with n-hexane and oil solution in n-hexane saturated with ACN, and (iii) partition of pesticides between ACN and oil were tested for the optimization of the highest pesticide recoveries with the lowest oil residue in the final extracts. Experimental tests were preformed in order to study the efficiency of different clean up procedures with N-Alumina, Florisil, C18, and ENVI-Carb solid-phase extraction (SPE) cartridges for the compounds analyzed by GC-nitrogen phosphorus detection. A second step of clean up was also performed for the compounds analyzed by GC-electron capture detection (ECD), by using phenyl-bonded silica (Ph), diol-bonded silica (Diol), cyanopropyl-bonded silica (CN), and amino propyl-bonded silica (NH2) SPE cartridges. LLE of the oil solution in hexane with ACN followed by an ENVI-Carb SPE clean up of the extract gave the best results for all target compounds. The ACN extract was additionally cleaned through a Diol-SPE cartridge for the determination of pesticides analyzed mainly by GC-ECD. Pesticide recoveries form virgin olive oil spiked with 20, 100, and 500 microg/kg concentrations of pesticides ranged from 70.9 to 107.4%. The proposed method featured good sensitivity, pesticide quantification limits were low enough, and the precision, expressed as relative standard deviation, ranged from 2.4 to 12.0%. The proposed method was applied successfully for the residue determination of the selected pesticides in commercial olive oil samples.

Chromatography, Gas↗