PubMed Health⌕ Search

PubMed · 15615956

Operator-dependent techniques for graded compression sonography to detect the appendix and diagnose acute appendicitis.

Abstract

OBJECTIVE: The objective of our prospective study was to evaluate the value of various operator-dependent techniques that allow graded compression sonography to detect normal or abnormal vermiform appendix. SUBJECTS AND METHODS: A total of 877 subjects were included in this study. This sample population consisted of two groups: 202 control subjects and 675 patients who were suspected of having acute appendicitis. If detection of the appendix failed after a sufficient number of trials using graded compression scanning, appropriate operator-dependent techniques were used to help graded compression scanning to increase the detectability of the appendix further. The detection rate for the appendix in both groups and the diagnostic accuracy for acute appendicitis were obtained. RESULTS: The initial graded compression sonography examination depicted the appendix in 170 (84%) of 202 subjects in the control group and 601 (89%) of the 675 patients in the patient group. We then added operator-dependent techniques to graded compression sonography for the remaining patients in whom the appendix could not be detected. The additional use of the posterior manual compression technique, low-frequency convex transducer, upward graded compression technique, or left oblique lateral decubitus change of body position allowed graded compression sonography to depict the appendix in an additional 10, eight, six, and four patients in the control group, respectively, and in an additional 27, 23, 11, and seven patients in the patient group. The number of identified appendixes was increased to 198 (98%) of the 202 patients in the control group and to 669 (99%) of the 675 patients in the patient group. Graded compression sonography with operator-dependent techniques in the patient group yielded a sensitivity of 99% (319/321 patients), specificity of 99% (350/354), and an accuracy of 99% (669/675) for acute appendicitis. CONCLUSION: The addition of various operator-dependent techniques to graded compression sonography is useful for allowing improved visualization of both normal and abnormal appendixes.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Jong Hwa Lee, Yoong Ki Jeong, Kwang Bo Park, Ji Kang Park, Ae Kyoung Jeong, Jae Cheol Hwang. 2005. Operator-dependent techniques for graded compression sonography to detect the appendix and diagnose acute appendicitis.. https://doi.org/10.2214/ajr.184.1.01840091

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

The effect of acute pain crisis on exhaled nitric oxide levels in children with sickle cell disease.

Exhaled nitric oxide (FE(NO)) has been shown to be decreased in children with sickle cell disease. We sought to evaluate the effect of sickle cell vaso-occlusive crisis (VOC) on FE(NO) levels. We measured FE(NO) levels in 42 children with sickle cell disease, 29 in their baseline health and 13 during an acute VOC. There was no difference in FE(NO) levels between children at baseline (15.12 +/- 9.32 ppb) and those during an acute VOC (15.68 +/- 7.26 ppb; P = 0.794). FE(NO) is not a useful marker of acute VOC in children with sickle cell disease.

Acute Disease↗

[Megadolichobasilar anomaly causing acute deafness with vertigo].

Megadolichobasilar anomaly, a dilatant arteriopathy of the basilar artery attributable to chronic arterial hypertension, can cause cranial nerve compression syndromes of the cerebellopontine angle or infarcts of the vertebrobasilar circulation. In this paper, we report on a patient with known megadolichobasilar anomaly and a partially thrombosed fusiform aneurysm of the basilar artery, who presented with acute-onset vertigo and subsequent deafness due to thromboembolic occlusion of the labyrinthine artery. Because of the vascular origin of the patient's symptoms, his vertigo disappeared over time while the deafness persisted.

Acute Disease↗

Retrieval of a leaflet escaped in a Tri-technologies bileaflet mechanical prosthetic valve.

The escape of the prosthetic heart valve disc is one of the causes of prosthetic dysfunction that requires emergency surgery. The removal of the embolized disc should be carried out because of the risk of a progressive extrusion on the aortic wall. Several imaging techniques can be used for the detection of the missing disc localization. In this report we describe a 32-year-old man who underwent mitral valve replacement with a Tri-technologies bileaflet valve three years ago, and was admitted in cardiogenic shock. Transesophageal echocardiography showed acute-onset massive mitral regurgitation. The patient underwent emergency replacement of the prosthetic valve. Only one of the two leaflets remained in the removed prosthetic valve. The missing leaflet could not be found within the cardiac cavity. The abdominal fluoroscopic study and plain radiography were unable to detect the escaped leaflet. The abdominal computed tomography scan and the ultrasound showed the escaped leaflet in the terminal portion of the aortic bifurcation. To retrieve the embolized disc laparotomy and aortotomy were performed three months later. The escaped leaflet shows a fracture of one of the pivot systems caused by structural failure. This kind of failure mode is usually the result of high stress concentration.

Acute Disease↗