Time-resolved fluorescence microscopy.

Abstract

In fluorescence microscopy, the fluorescence emission can be characterised not only by intensity and position, but also by lifetime, polarization and wavelength. Fluorescence lifetime imaging (FLIM) can report on photophysical events that are difficult or impossible to observe by fluorescence intensity imaging, and time-resolved fluorescence anisotropy imaging (TR-FAIM) can measure the rotational mobility of a fluorophore in its environment. We compare different FLIM methods: a chief advantage of wide-field time-gating and phase modulation methods is the speed of acquisition whereas for time-correlated single photon counting (TCSPC) based confocal scanning it is accuracy in the fluorescence decay. FLIM has been used to image interactions between proteins such as receptor oligomerisation and to reveal protein phosphorylation by detecting fluorescence resonance energy transfer (FRET). In addition, FLIM can also probe the local environment of fluorophores, reporting, for example, on the local pH, refractive index, ion or oxygen concentration without the need for ratiometric measurements.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Klaus Suhling, Paul M W French, David Phillips. 2004-11-11. Time-resolved fluorescence microscopy.. https://doi.org/10.1039/b412924p

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Spectroscopic techniques applied to the study of laminin fragments inserted into model membranes.

The influence of four laminin-derived peptides on bilayer organization is studied. Spectroscopic methods applied were based on pyrene fluorescence properties (quenching, I1/I3, and monomer/excimer equilibrium), asymmetric membrane fluorescence (NBD-PE/dithionite), and polarization fluorescence (TMA-DPH). Also, the ability of these peptides to release carboxyfluorescein entrapped in vesicles was determined. Results suggest that these peptides do not noticeably modify the packing and motion of lipids (in the gel state), but coat its surface, preventing penetration of quenchers and chemical reactants. Nevertheless, their presence promotes a soft release of entrapped CF after incubation at 37 degrees C.

Fluorescence Polarization↗

Real-time PCR measurement by fluorescence anisotropy.

We have developed an instrument for monitoring real-time PCR using fluorescence anisotropy, enabling an assay chemistry in which the fluorescence from a labeled primer elucidates amplification. The instrument holds the sample temperature constant to within +/-0.03 degrees C during measurement in the extension phase of each PCR cycle and achieves 0.116 mP FA resolution. Primer conjugation with Alexa-Fluor 488, when compared with other fluorophores, is shown to provide the greatest FA range between primer and product. Comparable reproducibility and linearity of the crossing point for a range of target copy numbers is observed between the FA-based assay run in our instrument and the SYBR green assay run in commercial instrumentation. Reproducibility is also consistent with Poisson-distributed experimental error in aliquoting starting copies, a theoretical limit to instrument/assay performance.

Fluorescence Polarization↗