PubMed Health⌕ Search

PubMed · 15644758

Defining pseudoarthrosis in the cervical spine with differing motion thresholds.

Abstract

STUDY DESIGN: Calculate the apparent pseudarthrosis rate for anteriorly plated cervical spine fusions using different threshold levels of intervertebral rotation. OBJECTIVES: Determine whether the apparent pseudarthrosis rate depends on the amount of intervertebral rotation used to characterize a fusion as a pseudarthrosis. SUMMARY OF BACKGROUND DATA: Intervertebral motion at a spine fusion site is an important outcome measure in most spine fusion research studies. Intervertebral motion measures are used to determine if a device can be sold for use in spine fusion surgery. There is no consensus on how much motion is too much motion at a spine fusion site, and the intervertebral motion threshold that is used to define a pseudarthrosis is arbitrary. There are only limited data on the dependence of the pseudarthrosis rate on the threshold used to define a pseudarthrosis. METHODS: Intervertebral motion at the fusion site was measured from flexion extension radiographs taken 1 year after cervical spine fusion using anterior plates and allograft in 200 patients. The number of cases where intervertebral motion at the fusion site exceeded thresholds between 1 degrees and 4 degrees were calculated. RESULTS.: The apparent pseudarthrosis rate varied from 6% when the intervertebral motion threshold was 4 degrees to 44% when the intervertebral motion threshold was 1 degrees . CONCLUSIONS: The apparent pseudarthrosis rate was highly dependent on the threshold of motion used to define a pseudarthrosis.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

John A Hipp, Charles A Reitman, Nicholas Wharton. 2005-01-15. Defining pseudoarthrosis in the cervical spine with differing motion thresholds.. https://doi.org/10.1097/01.brs.0000151011.32573.f1

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Stacked plating for metadiaphyseal fractures of the distal radius: a technique report.

Combined injuries of the distal radius and shaft are rare, are usually caused by high energy, and pose a surgical dilemma. Surgical tactics and implants that are routinely used either for isolated fractures of the distal radius or for fractures of the radial shaft are often not applicable for this combined injury. We describe a technique of dual-stacked plating for these metadiaphyseal fractures and its use in two patients.

Bone Plates↗

Plate fixation of olecranon osteotomies.

The management of intra-articular distal humeral fractures remains a difficult surgical problem. Although an olecranon osteotomy provides excellent exposure for management of these fractures, a number of complications can occur after the creation and repair of the osteotomy including nonunion, malunion, hardware failure, and pain secondary to prominent hardware. In an effort to reduce the incidence of these complications, the senior authors now use contoured 3.5 mm reconstruction plates for the fixation of their apex-distal chevron olecranon osteotomies. Two surgeons at a single institution used this technique of exposure on a series of 17 consecutive patients with intra-articular distal humerus fractures between 1996 and 1999. In this series, all osteotomies united. There was one complication related specifically to the osteotomy: one of the screws in the plate penetrated the proximal radioulnar joint, interfering with forearm rotation; a second procedure was required to shorten the screw. Only one of the 17 patients requested plate removal during the 32 month (average) follow-up period. Plate fixation of olecranon osteotomies using a 3.5 mm reconstruction plate provides a construct with predictable healing and few complications. The overall results using this technique are comparable with other reported methods in the literature.

Bone Plates↗