Monitor position in laparoscopic surgery.

Abstract

BACKGROUND: One of the key problems in laparoscopy is the ergonomic positioning of the monitor. In this study we tested task performance and muscle strain of subjects in relation to monitor position during laparoscopic surgery. METHODS: Eighteen subjects simulated laparoscopic suturing by threading tiny pearls with a curved needle. This was repeated in three monitor positions (15 min each): frontal at eye level (A), frontal in height of the operating field (B), and 45 degrees to the right side at eye level (C). Subjects were not allowed to turn their heads during these sessions. After the test they were asked for their preferred monitor position. During all tests the electromyographic (EMG) activity of the main neck muscles was recorded and the number of pearls was counted. RESULTS: The EMG activity was significantly lower for position A compared to positions C and B (p < 0.05). No significant difference was found between positions B and C. The number of threaded pearls as an indicator for task performance was highest for position B. The difference was statistically significant compared to position C (p = 0.0008) but not between positions A and C (p = 0.0508) or A and B (p = 0.0575). When asked for the preferred monitor position, nine subjects chose two monitors in the frontal positions A and B. No subject preferred the monitor at the side position (C). CONCLUSION: Regarding EMG data, the monitor positioned frontal at eye level is preferable. Reflecting personal preferences of subjects and task performance, it should be of advantage to place two monitors in front of the surgeon: one in position A for lowest neck strain and the other in position B for difficult tasks with optimal task performance. The monitor position at the side is not advisable.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

U Matern, M Faist, K Kehl, C Giebmeyer, G Buess. 2005-01-10. Monitor position in laparoscopic surgery.. https://doi.org/10.1007/s00464-004-9030-7

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Practical assessment of the display performance of radiology workstations.

The performance of 14 primary clinical display monitor workstations in use in the Radiology Department of a large acute NHS Trust was assessed using the methods and guidelines described by the American Association of Physicists in Medicine Task Group 18. Tests undertaken included the measurement of ambient light, display uniformity, luminance ratio, luminance response, maximum luminance and spatial resolution. Four display monitors failed to meet at least one of the test's guideline tolerances. In addition a number of display monitors were found to be operating at settings that might reduce their useful life span. These devices were either replaced or recalibrated by the installers, or were subject to local adjustment to ensure applicable standards were met. Consequently the study suggests that quality assurance testing of display monitors used for image reporting is necessary and valuable to ensure that images are viewed at an appropriate standard.

Computer Terminals↗