Abstract

SUMMARY BACKGROUND DATA: To inform surgeons about the practical issues to be considered for successful integration of virtual reality simulation into a surgical training program. The learning and practice of minimally invasive surgery (MIS) makes unique demands on surgical training programs. A decade ago Satava proposed virtual reality (VR) surgical simulation as a solution for this problem. Only recently have robust scientific studies supported that vision METHODS: A review of the surgical education, human-factor, and psychology literature to identify important factors which will impinge on the successful integration of VR training into a surgical training program. RESULTS: VR is more likely to be successful if it is systematically integrated into a well-thought-out education and training program which objectively assesses technical skills improvement proximate to the learning experience. Validated performance metrics should be relevant to the surgical task being trained but in general will require trainees to reach an objectively determined proficiency criterion, based on tightly defined metrics and perform at this level consistently. VR training is more likely to be successful if the training schedule takes place on an interval basis rather than massed into a short period of extensive practice. High-fidelity VR simulations will confer the greatest skills transfer to the in vivo surgical situation, but less expensive VR trainers will also lead to considerably improved skills generalizations. CONCLUSIONS: VR for improved performance of MIS is now a reality. However, VR is only a training tool that must be thoughtfully introduced into a surgical training curriculum for it to successfully improve surgical technical skills.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Anthony G Gallagher, E Matt Ritter, Howard Champion, Gerald Higgins, Marvin P Fried, Gerald Moses, C Daniel Smith, Richard M Satava. 2005. Virtual reality simulation for the operating room: proficiency-based training as a paradigm shift in surgical skills training.. https://doi.org/10.1097/01.sla.0000151982.85062.80

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

A low glycaemic index breakfast cereal preferentially prevents children's cognitive performance from declining throughout the morning.

This study investigated whether the glycaemic index (GI) of breakfast cereal differentially affects children's attention and memory. Using a balanced cross-over design, on two consecutive mornings 64 children aged 6-11 years were given a high GI cereal and a low GI cereal in a counterbalanced order. They performed a series of computerised tests of attention and memory, once prior to breakfast and three times following breakfast at hourly intervals. The results indicate that children's performance declines throughout the morning and that this decline can be significantly reduced following the intake of a low GI cereal as compared with a high GI cereal on measures of accuracy of attention (M=-6.742 and -13.510, respectively, p<0.05) and secondary memory (M=-30.675 and -47.183, respectively, p<0.05).

Attention↗

Inhibitory control test is a simple method to diagnose minimal hepatic encephalopathy and predict development of overt hepatic encephalopathy.

OBJECTIVES: To compare inhibitory control test (ICT), a simple/rapid test of attention, to a standard psychometric battery (SPT) to diagnose minimal hepatic encephalopathy (MHE) and predict development of overt hepatic encephalopathy (OHE) in cirrhotic patients. METHODS: Fifty nonalcoholic cirrhotics and 50 age/educational-status-matched controls were given ICT and SPT in the same sitting. Performance impaired beyond two standard deviations of controls was considered MHE in cirrhotics. ICT results (lure/target response and lures/person) were compared between controls and cirrhotics and within cirrhotics with/without MHE. Receiver-operating characteristic analysis was used to study ICT for MHE diagnosis. Twenty subjects were administered SPT and ICT twice to assess test-retest reliability. All cirrhotics were followed routinely for the development of OHE. RESULTS: Cirrhotics performed worse than controls on SPT and ICT. Using SPT, 39 cirrhotics had MHE. ICT was administered faster than SPT (15 vs 37 min). Cirrhotics with MHE had significantly higher lure (28%vs 3%) and lower target response (91%vs 96%) compared with those without MHE. Lure/person >5 had 90% sensitivity/specificity for MHE diagnosis. AUC for receiver-operating characteristic for lures alone was 95.8%. Lure and target responses were highly correlated (r= 0.9) between sessions showing high test-retest reliability. Five (10%) patients developed OHE on f/u of 26 +/- 10 months; all five had been diagnosed with MHE using ICT and SPT. None of the five patients with discordant results on SPT and ICT developed OHE. CONCLUSIONS: ICT has good sensitivity/specificity for MHE diagnosis, is reliable and is equivalent to SPT for predicting OHE development.

Attention↗