Abstract

BACKGROUND CONTEXT: Painful lumbar disc degeneration is one of the most common ailments treated by spine surgeons. Currently, early disc disease and herniation are often treated with microdiscectomy. Late disc degeneration is usually treated with arthrodesis. With the advent of new technology and techniques in lumbar disc arthroplasty, interest in preserving spinal motion at degenerated motion segments has increased. The goals of lumbar disc arthroplasty are to provide long-term pain relief at the degenerated disc level, to restore disc height to protect neural elements and to preserve motion to prevent posterior facet arthropathy and adjacent segment disease. PURPOSE: The purpose of this review is to examine the anatomy and biomechanics of the lumbar motion segment to determine the features that successful disc arthroplasty prosthesis must possess. In addition, the early clinical results of three prostheses currently being used in humans are reviewed. STUDY DESIGN/SETTING: Review of the literature. METHODS: A systematic review of Medline for articles related to lumbar disc arthroplasty was conducted up to and including journal articles published in August 2003. In addition, the abstracts from the annual meetings of the North American Spine Society and Scoliosis Research Society from 1998 to 2003 were searched. The literature was then reviewed and summarized. RESULTS/CONCLUSIONS: Short-term results of lumbar disc arthroplasty as measured by pain relief and disability are good in some studies. Implants are relatively safe in the short term, and with newer designs complications are usually related to the surgical approach rather than early implant failure. Recovery times appear to be shorter than arthrodesis. Despite the relatively good early clinical results of these devices, questions remain about the long-term efficacy in pain relief and maintenance of motion, the results of randomized comparative trials with fusion and the life span of the devices. In addition, late sequelae and revision options are unknown. Current indications for lumbar disc arthroplasty are in the setting of a Food and Drug Administration trial in young, nonosteoporotic patients with one or two level symptomatic disc degeneration without severe facet arthropathy, segmental instability or neural element compression requiring a posterior decompression.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Seth C Gamradt, Jeffrey C Wang. Lumbar disc arthroplasty.. https://doi.org/10.1016/j.spinee.2004.09.006

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Guidelines for the replacement of temporomandibular joints in the United Kingdom.

BAOMS has requested that guidelines be formulated for the replacement of the temporomandibular joint (TMJ). This is an expensive and technique sensitive method of TMJ reconstruction and in the current climate warrants an agreed approach. The following document states the indications and contraindications for this technique as discussed and agreed amongst surgeons currently carrying out this procedure in the UK.

Arthroplasty, Replacement↗

Influence of changes in the composition of an acrylic bone cement on its polymerization kinetics.

It has been suggested in the literature that a lower polymerization rate of an acrylic bone cement is favorable for the in vivo longevity of a cemented arthroplasty. The present work was a study of the influence of three changes in the composition of an acrylic bone cement (when taken separately) on the cement polymerization rate at 37 degrees C (assumed to be the temperature in the bone bed during a cemented arthroplasty) [k']. The changes were the amount of copolymer as a proportion of the total powder weight (in cements in which there is a copolymer in the powder), the amount of DMPT as a proportion of the total volume of the liquid monomer, and the accelerator. k' was calculated using values of the activation energy and the frequency factor (assuming the polymerization reaction is Arrhenius in nature) that were computed from measurements made using the nonisothermal mode of differential scanning calorimetry. Statistical analysis (one-way ANOVA, with Bonferroni correction, and factorial ANOVA) of the k' values showed that the change in accelerator had a significant influence on k'. The importance of this finding, together with results from two relevant literature reports, is discussed within the context of the use of modified bone cements in cemented arthroplasties.

Arthroplasty, Replacement↗

Glenohumeral kinematics following total shoulder arthroplasty: a finite element investigation.

The osseous geometry of the glenohumeral joint is naturally nonconforming and minimally constrained, and the joint's stability is maintained by action of the rotator cuff muscles. Damage to these muscles is often associated with joint degeneration, and a variety of glenoid prostheses have been developed to impart varying degrees of stability postoperatively. The issues of conformity and constraint within the artificial shoulder have been addressed through in vivo and in vitro studies, although few computational models have been presented. The current investigation presents the results of three-dimensional finite element analyses of the total shoulder joint and the effects of design parameters upon glenohumeral interaction. Conformity was shown not to influence the loads required to destabilize the joint, although it was the principal factor determining the magnitude of humeral head translation. Constraint was found to correlate linearly with the forces required to dislocate the humeral head, with higher constraint leading to slightly greater humeral migration at the point of joint instability. The model predicts that patients with a dysfunctional supraspinatus would experience frequent eccentric loading of the glenoid, especially in the superior direction, which would likely lead to increased fixation stresses, and hence, a greater chance of loosening. For candidates with an intact rotator cuff, the models developed in this study predict that angular constraints of at least 14 degrees and 6.5 degrees in the superoinferior and anteroposterior axes are required to provide stable unloaded abduction of the humerus, with larger constraints of 18 degrees and 10 degrees necessitated by a dysfunctional supraspinatus. The tools developed during this study can be used to determine the capacity for different implant designs to provide resistance to excessive glenohumeral translations and reduce the potential for instability of the joint, allowing surgeons to optimize postoperative functional gains on a patient by patient basis.

Arthroplasty, Replacement↗