PubMed Health⌕ Search

PubMed · 15654315

[Analysis of repeated binary data: sensitivity to missing data].

Abstract

BACKGROUND: In longitudinal studies, it is extremely rare that all the planned measurements are actually performed. Missing data are often consecutive to drop-outs, but may also be intermittent. In both cases, the analysis of incomplete data necessarily requires assumptions that are generally unverifiable, and the need for sensitivity analyses has been advocated over the past few years. In this article, the attention will be given to longitudinal binary data. METHODS: A method is proposed, which is based on a log-linear model. A sensitivity parameter is introduced that represents the relationship between the response mechanism and the missing data mechanism. It is recommended not to estimate this parameter, but to consider a range of plausible values, and to estimate the parameters of interest conditionally on these plausible values. This allows to assess the sensitivity of the conclusion of a study to various assumptions regarding the missing data mechanism. RESULTS: This method was applied to a randomized clinical trial comparing the efficacy of two treatment regimens in patients with persistent asthma. The sensitivity analysis showed that the conclusion of this study was robust to missing data.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

P Minini, M Chavance. 2004. [Analysis of repeated binary data: sensitivity to missing data].. https://doi.org/10.1016/s0398-7620(04)99081-5

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

[Report on the 89th Scientific Assembly and Annual Meeting of the Radiological Society of North America--balance between the time sensitivity profile and the slice sensitivity profile in multi-slice helical scanning].

PURPOSE: With multi-slice helical scanning, increasing helical pitch causes changes in the effective slice sensitivity profile and thus in a thickening of the effective slice thickness. However, the increase in helical pitch alters the time sensitivity profile, thereby decreasing the effective scan time. In this paper we report the results of our research concerning the setting of optimum conditions to resolve this issue. METHOD AND MATERIALS: The experiment was conducted with a moving phantom. The movement showed a variety of changes. RESULTS: When the subject was not in motion, increases in helical pitch resulted in deterioration in the image quality of the CT image. However, when the subject was in motion increases in helical pitch improved image quality. CONCLUSION: The general belief until now has been that helical pitch should be decreased in order to improve CT image quality. However, in the case of a moving subject, reduced helical pitch leads to deterioration in the time resolution and thus to a deterioration in the image quality. Through this study we have acquired an understanding of which helical pitch value is optimal in terms of the subject's rate of movement.

Sensitivity and Specificity↗

Coupling of a large-size capillary column with an electrospray mass spectrometer. A reliable and sensitive sheath flow capillary electrophoresis-mass spectrometry interface.

The concept of interfacing a large-size column for capillary electrophoresis (CE) to electrospray ionization mass spectrometry (ESI-MS) for robust and automatic CE-MS operation is reported. Both standard ionspray interface and microionspray interface have been modified to operate in a sheath flow pattern to overcome the common stability problem in CE-MS coupling. To make the interface sensitive, a step-down stainless steel tube with smaller inner diameter and tapered tip was incorporated onto a larger tube embracing the CE column via cold soldering. The devices were evaluated for quantitative analysis of nucleotides at femtomole level and stable analytical performance in peptide profiling.

Sensitivity and Specificity↗