PubMed Health⌕ Search

PubMed · 15674293

How the Venus flytrap snaps.

Abstract

The rapid closure of the Venus flytrap (Dionaea muscipula) leaf in about 100 ms is one of the fastest movements in the plant kingdom. This led Darwin to describe the plant as "one of the most wonderful in the world". The trap closure is initiated by the mechanical stimulation of trigger hairs. Previous studies have focused on the biochemical response of the trigger hairs to stimuli and quantified the propagation of action potentials in the leaves. Here we complement these studies by considering the post-stimulation mechanical aspects of Venus flytrap closure. Using high-speed video imaging, non-invasive microscopy techniques and a simple theoretical model, we show that the fast closure of the trap results from a snap-buckling instability, the onset of which is controlled actively by the plant. Our study identifies an ingenious solution to scaling up movements in non-muscular engines and provides a general framework for understanding nastic motion in plants.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Yoël Forterre, Jan M Skotheim, Jacques Dumais, L Mahadevan. 2005-01-27. How the Venus flytrap snaps.. https://doi.org/10.1038/nature03185

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Finite element analysis of a transmandibular implant.

Finite element analysis (FEA) was used to study the influence of bony height and baseplate effect on the transmandibular implant (TMI). FEA was used to assess the stress distribution in the mandible, with and without a baseplate. Forces were applied to the center of a bar space. The von Mises stress (SEQV) was displayed in bone, and shear stress also was measured. Tensile stress was always seen at the so-called saddle area; compressive stress was seen at the inferior border. Tensile strain at the saddle area of a 6-mm height mandible is always 9.1 times greater (corresponding to more SEQV) than that of an 18-mm mandible. At same bone heights, saddle area stresses are similar with or without a baseplate. However, stress at the lateral transossseous post interface with bone was significantly different between different bone height groups. Shear stress around the lateral transossseous post was smaller than does the SEQV of the same site. Decreased bone height dramatically increases stress at the saddle area independent of the baseplate presence. These data suggest that bone apposition is found in the severely atrophic mandibles. Thus, there is no need for a baseplate in a slight to mild atrophic mandible.

Biomechanical Phenomena↗

Percutaneous vertebroplasty and kyphoplasty for the stand-alone augmentation of osteoporosis-induced vertebral compression fractures: present status and future directions.

Enormous research efforts are being expended on two minimally invasive procedures: percutaneous vertebroplasty (VP) and kyphoplasty (KP). The present report, which is a detailed critical review of VP and KP that emphasizes their biomechanics aspects, is divided into six parts. In the first two parts, succinct descriptions are given of osteoporosis-induced vertebral body (VB) compression fractures as the underlying pathology to be treated with VP and KP, the theory of VP and KP, and the techniques used in performing these procedures. Concerns about VP and KP, such as the high radiation exposure burden that may be imposed on both patient and medical personnel and extravasation of the injectable bone cement, are discussed in the third part. Detailed discussions of fourteen issues/questions, such as the extent to which VP or KP affects various biomechanical measures of the augmented VB and those adjacent to it and the appropriate volume of the cement to use, are presented in the fourth part. Ideas for future research, such as development of a new generation of injectable bone cements and identification of an appropriate animal model, are covered in the fifth part. The final section contains a summary of the most salient points/observations made in the report.

Biomechanical Phenomena↗

Compliant leg behaviour explains basic dynamics of walking and running.

The basic mechanics of human locomotion are associated with vaulting over stiff legs in walking and rebounding on compliant legs in running. However, while rebounding legs well explain the stance dynamics of running, stiff legs cannot reproduce that of walking. With a simple bipedal spring-mass model, we show that not stiff but compliant legs are essential to obtain the basic walking mechanics; incorporating the double support as an essential part of the walking motion, the model reproduces the characteristic stance dynamics that result in the observed small vertical oscillation of the body and the observed out-of-phase changes in forward kinetic and gravitational potential energies. Exploring the parameter space of this model, we further show that it not only combines the basic dynamics of walking and running in one mechanical system, but also reveals these gaits to be just two out of the many solutions to legged locomotion offered by compliant leg behaviour and accessed by energy or speed.

Biomechanical Phenomena↗