PubMed Health⌕ Search

PubMed · 15690145

[Perioperative coagulation diagnostics].

Abstract

The main diagnostic tool for the preoperative identification of patients with an increased risk of bleeding or thrombosis is the patient history. Laboratory diagnostics should only be performed if a bleeding diathesis is suspected from patient history or clinical symptoms of bleeding, or if an adequate patient history cannot be performed. Measurement of prothrombin time, aPTT, or bleeding time as a general preoperative screening procedure is neither cost-effective nor efficient for the identification of patients with increased bleeding risk. Normal values of prothrombin time and aPTT do not exclude the most prevalent bleeding disorder, von Willebrand's disease. A normal platelet count does not exclude a severe platelet function defect. Selection of specific laboratory assays is performed on the basis of the individual patient history and clinical picture; laboratory 'profiles' can be defined for some specific clinical conditions. In some cases, patients should be referred to a specialized coagulation clinic for further diagnostics and treatment planning. Preoperative laboratory diagnostics for thrombophilia are not necessary in most cases. The decision for intensified antithrombotic measures is made according to patient history and the postoperative clinical course.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

C-E Dempfle. 2005. [Perioperative coagulation diagnostics].. https://doi.org/10.1007/s00101-005-0802-9

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Molecular characterization of an Italian patient with plasminogen deficiency and ligneous conjunctivitis.

Plasminogen deficiency is a rare disease characterized by ligneous conjunctivitis and infections. We observed a 3-year-old Italian boy presenting ligneous conjunctivitis and low plasma levels of plasminogen. Twenty-three different mutations on the PLG gene have been reported to date, but mutation analysis had been troublesome for the presence of highly homologous genes. The aim of the study was to identify the underlying mutation avoiding coamplification of unwanted genetic materials using a long polymerase chain reaction strategy, instead of the previously reported subcloning methods. By this simple strategy the complete sequence analysis of PLG gene was performed, and a previously reported missense homozygous mutation (K19E) was identified.

Blood Coagulation Disorders↗

Diagnosis of early coagulation abnormalities in trauma patients by rotation thrombelastography.

BACKGROUND: Reagent-supported thromboelastometry with the rotation thrombelastography (e.g. ROTEM) is a whole blood assay that evaluates the visco-elastic properties during blood clot formation and clot lysis. A hemostatic monitor capable of rapid and accurate detection of clinical coagulopathy within the resuscitation room could improve management of bleeding after trauma. OBJECTIVES: The goals of this study were to establish whether ROTEM correlated with standard coagulation parameters to rapidly detect bleeding disorders and whether it can help to guide transfusion. METHODS: Ninety trauma patients were included in the study. At admission, standard coagulation assays were performed and ROTEM parameters such as clot formation time (CFT) and clot amplitude (CA) were obtained at 15 min (CA(15)) with two activated tests (INTEM, EXTEM) and at 10 min (CA(10)) with a test analyzing specifically the fibrin component of coagulation (FIBTEM). RESULTS: Trauma induced significant modifications of coagulation as assessed by standard assays and ROTEM. A significant correlation was found between prothrombin time (PT) and CA(15)-EXTEM (r = 0.66, P < 0.0001), between activated partial thromboplastin time and CFT-INTEM (r = 0.91, P < 0.0001), between fibrinogen level and CA(10)-FIBTEM (r = 0.85, P < 0.0001), and between platelet count and CA(15)-INTEM (r = 0.57, P < 0.0001). A cutoff value of CA(15)-EXTEM at 32 mm and CA(10)-FIBTEM at 5 mm presented a good sensitivity (87% and 91%) and specificity (100% and 85%) to detect a PT > 1.5 of control value and a fibrinogen less than 1 g L(-1), respectively. CONCLUSIONS: ROTEM is a point-of-care device that rapidly detects systemic changes of in vivo coagulation in trauma patients, and it might be a helpful device in guiding transfusion.

Blood Coagulation Disorders↗