Universal back-projection algorithm for photoacoustic computed tomography.

Abstract

We report results of a reconstruction algorithm for three-dimensional photoacoustic computed tomography. A universal back-projection formula is presented for three types of imaging geometries: planar, spherical, and cylindrical surfaces. A solid-angle weighting factor is introduced in the back-projection formula to compensate for the variations of detection views. A method for implementing this algorithm is described. Numerical simulation is used to demonstrate the performance of the algorithm.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Minghua Xu, Lihong V Wang. 2005-01-19. Universal back-projection algorithm for photoacoustic computed tomography.. https://doi.org/10.1103/physreve.71.016706

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

A novel photoacoustic tomography based on a time-resolved technique and an acoustic lens imaging system.

A novel photoacoustic (PA) tomographic method, which is based on a time-resolved technique and an acoustic lens imaging system, is presented in this paper. A YAG laser operating at 532 nm with a 7 ns pulse width and 10 mJ optical pulse is employed as the excitation source to irradiate the tissue. PA signals generated from the tissue are imaged onto a multi-element linear array transducer with an acoustic lens. A 64 electronic switch is efficiently used for changing the parallel PA signals into a series. The proposed method directly provides PA images without any complex reconstruction algorithms. With the time-resolved technique, tomographic imaging can be achieved successfully. The results show that the images agree well with the original samples.

Acoustics↗

Acoustic quality of cry in very-low-birth-weight infants at the age of 1 1/2 years.

BACKGROUND: Infant cry characteristics reflect the integrity of the central nervous system. Previous studies have shown that preterm infants and infants with neurological conditions have different cry characteristics such as fundamental frequency compared to healthy full-term infants. Cry characteristics of preterm infants after the first year of life have not been studied. AIMS: The aim of this study was to assess the quality of cry in 1 1/2-year-old very-low-birth-weight infants (VLBWI, < or =1500 g at birth). STUDY SUBJECTS AND DESIGN: Study groups included 21 VLBWI and 25 healthy full-term controls. Thirty seconds of pain cry after vaccination was recorded at well-baby clinics. The first cry utterance was acoustically analyzed using Praat software. The quality of cry was compared between the groups. In addition, the association of cry quality to patient characteristics, to developmental outcome, and to findings in brain imaging studies of the VLBWI was studied. RESULTS: The cry response was elicited in 20 of the 21 VLBWI and in 20 out of 25 full-term infants. VLBWI had higher minimum fundamental frequency and fourth formant values. Patient characteristics that were associated with cry quality were 5-min Apgar scores, the occurrence of bronchopulmonary dysplasia, Bayley Psychomotor Index scores at 12 months, and current weight and head circumference. CONCLUSIONS: Differences found between the study groups were not explained primarily by brain pathology or by patient characteristics, so it seems that prematurity has an impact on cry quality still at the age of 1 1/2 years.

Acoustics↗

Comparison of lung sound transducers using a bioacoustic transducer testing system.

Sensors used for lung sound research are generally designed by the investigators or adapted from devices used in related fields. Their relative characteristics have never been defined. We employed an artificial chest wall with a viscoelastic surface and a white noise signal generator as a stable source of sound to compare the frequency response and pulse waveform reproduction of a selection of devices used for lung sound research. We used spectral estimation techniques to determine frequency response and cross-correlation of pulses to determine pulse shape fidelity. The sensors evaluated were the Siemens EMT 25 C accelerometer (Siemens); PPG 201 accelerometer (PPG); Sony ECM-T150 electret condenser microphone with air coupler (air coupler; with cylindrical air chambers of 5-, 10-, and 15-mm diameter and conical air chamber of 10-mm diameter); Littman classic stethoscope head (Littman) connected to an electret condenser microphone; and the Andries Tek (Andries) electronic stethoscope. We found that the size and shape of the air coupler chamber to have no important effect on the detected sound. The Siemens, air coupler, and Littman performed similarly with relatively flat frequency responses from 200 to 1,200 Hz. The PPG had the broadest frequency response, with useful sensitivity extending to 4,000 Hz. The Andries' frequency response was the poorest above 1,000 Hz. Accuracy in reproducing pulses roughly corresponded with the high-frequency sensitivity of the sensors. We conclude that there are important differences among commonly used lung sound sensors that have to be defined to allow the comparison of data from different laboratories.

Acoustics↗