PubMed · 15702601

A linear mixed-effects calibration in qualifying experiments.

Abstract

In many applications, controls are used to monitor the process or experiment and to assess whether the process is in control or the experiment is valid. In this case, the traditional fixed-effects calibration is usually not adequate, but a mixed-effects model is appropriate. In this article, a linear mixed-effects calibration model is considered to qualify an experiment. Two estimating methods for the controls based on maximum likelihood and restricted maximum likelihood are proposed. The bias and mean squared error performances are studied by simulation. Five different methods to construct confidence intervals for the controls are compared. A dataset is used to demonstrate the advantages of the mixed-effects model.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Jason J Z Liao. 2005. A linear mixed-effects calibration in qualifying experiments.. https://doi.org/10.1081/bip-200040800

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Determination of rizatriptan in human plasma by liquid chromatographic-eletrospray tandem mass spectrometry: application to a pharmacokinetic study.

A sensitive liquid chromatographic-tandem mass spectrometry(LC-MS/MS) method was developed for the determination of rizatriptan in human plasma. The analytes were extracted from plasma samples by liquid-liquid extraction, separated on a Zorbax XDB C8 column (150 x 4.6 mm i.d.) and detected by tandem mass spectrometry with an electrospray ionization interface. Zomitriptan was used as the internal standard. The method had a lower limit of quantitation of 50 pg/mL for rizatriptan, which showed more sensitivity and speed of analysis compared with reported methods. The within- and between-day precision was measured to be below 11.71% and accuracy between -5.87 and 0.86% for all quality control samples. This quantitation method was successfully applied to the evaluation of the pharmacokinetic profiles of rizatriptan after single oral administration of 5, 10 and 15 mg rizatriptan tablets to 10 healthy volunteers (five males and five females).

Calibration↗

Method development and validation for the GC-FID assay of p-cymene in tea tree oil formulation.

This paper describes the development and validation of an isothermal gas chromatography-flame ionisation detection (GC-FID) method for the assay of pure tea tree oil. The chromatographic conditions of the method employ a 5% carbowax packed column (20 m x 0.25 mm), isothermal elution with hydrogen at a column flow of 36 ml/min, injector and detector temperature at 220 degrees C and oven temperature at 100 degrees C, and a 1.5 microl injection volume. Samples and standard were diluted in hexane. The calibration curve for p-cymene was linear (r2=0.9995) from 20 to 120% range of the analytical concentration of 100 microg/ml. The precision of this method was calculated as the relative standard deviation (R.S.D.) was 0.66% (n=6). The R.S.D. for intermediate precision study was 0.13 and recovery of the p-cymene ranged between 93.39 and 97.86%. The limits of detection and quantitation were determined to be 2.08 and 10.39 ng/ml, respectively.

Calibration↗

Simultaneous determination of 10 major flavonoids in Dalbergia odorifera by high performance liquid chromatography.

A reversed-phase liquid chromatographic method was developed for the simultaneous quantification of 10 major flavonoids, namely butin, (3R)-4'-methoxy-2',3,7-trihydroxyisoflavanone, liquiritigenin, melanettin, violanone, vistitone, formononetin, dalbergin, sativanone and medicarpin in the heartwood of Dalbergia odorifera, an important traditional Chinese medicine. Samples were extracted with 60% methanol. The optimal conditions of separation and detection were achieved on an Agilent Zorbax SB-C18 column (250 mm x 4.6 mm, 5 microm) with a gradient of acetonitrile and 0.3% (v/v) aqueous acetic acid, at a flow rate of 0.8 ml/min, detected at 275 nm. The complete separation was obtained within 55 min for the 10 target compounds. All calibration curves showed good linearity (r2>0.999) within test ranges. The assay was reproducible with overall intra- and inter-day variation of less than 3%. The mean recovery of the method was 100+/-10%, with R.S.D. less than 5%. The current assay method was considered to be suitable for the quality control of D. odorifera samples and could be readily utilized for the determination of the active principles present in this medicinal herb.

Calibration↗