PubMed Health⌕ Search

PubMed · 15713289

Muscle forces predicted using optimization methods are coordinate system dependent.

Abstract

Optimization methods are widely used to predict in vivo muscle forces in musculoskeletal joints. Moment equilibrium at the joint center (usually chosen as the origin of the joint coordinate system) has been used as a constraint condition for optimization procedures and the joint reaction moments were assumed zero. This study, through the use of a three-dimensional elbow model, investigated the effect of coordinate system origin (joint center) location on muscle forces predicted using a nonlinear static optimization method. The results demonstrated that moving the origin of the coordinate system medially and laterally along the flexion-extension axis caused dramatic variations in the predicted muscle forces. For example, moving the origin of the coordinate system from a position 5mm medial to 5mm lateral of the geometric elbow center caused the predicted biceps force to vary from 12% to 46% and the brachialis force to vary from 80% to 34% of the total muscle loading. The joint reaction force reduced by 24% with this medial to lateral variation of the coordinate system origin location. This data revealed that the muscle forces predicted using the optimization method are sensitive to the coordinate system origin location due to the zero joint reaction moment assumption in the moment constraint condition. For accurate prediction of muscle load distributions using optimization methods, it is necessary to determine the accurate coordinate system origin location where the condition of a zero joint reaction moment is satisfied.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Janine E Pierce, Guoan Li. 2005. Muscle forces predicted using optimization methods are coordinate system dependent.. https://doi.org/10.1016/j.jbiomech.2004.05.016

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Finite element analysis of a transmandibular implant.

Finite element analysis (FEA) was used to study the influence of bony height and baseplate effect on the transmandibular implant (TMI). FEA was used to assess the stress distribution in the mandible, with and without a baseplate. Forces were applied to the center of a bar space. The von Mises stress (SEQV) was displayed in bone, and shear stress also was measured. Tensile stress was always seen at the so-called saddle area; compressive stress was seen at the inferior border. Tensile strain at the saddle area of a 6-mm height mandible is always 9.1 times greater (corresponding to more SEQV) than that of an 18-mm mandible. At same bone heights, saddle area stresses are similar with or without a baseplate. However, stress at the lateral transossseous post interface with bone was significantly different between different bone height groups. Shear stress around the lateral transossseous post was smaller than does the SEQV of the same site. Decreased bone height dramatically increases stress at the saddle area independent of the baseplate presence. These data suggest that bone apposition is found in the severely atrophic mandibles. Thus, there is no need for a baseplate in a slight to mild atrophic mandible.

Biomechanical Phenomena↗

Percutaneous vertebroplasty and kyphoplasty for the stand-alone augmentation of osteoporosis-induced vertebral compression fractures: present status and future directions.

Enormous research efforts are being expended on two minimally invasive procedures: percutaneous vertebroplasty (VP) and kyphoplasty (KP). The present report, which is a detailed critical review of VP and KP that emphasizes their biomechanics aspects, is divided into six parts. In the first two parts, succinct descriptions are given of osteoporosis-induced vertebral body (VB) compression fractures as the underlying pathology to be treated with VP and KP, the theory of VP and KP, and the techniques used in performing these procedures. Concerns about VP and KP, such as the high radiation exposure burden that may be imposed on both patient and medical personnel and extravasation of the injectable bone cement, are discussed in the third part. Detailed discussions of fourteen issues/questions, such as the extent to which VP or KP affects various biomechanical measures of the augmented VB and those adjacent to it and the appropriate volume of the cement to use, are presented in the fourth part. Ideas for future research, such as development of a new generation of injectable bone cements and identification of an appropriate animal model, are covered in the fifth part. The final section contains a summary of the most salient points/observations made in the report.

Biomechanical Phenomena↗

Effect of oxygen inhibition on composite repair strength over time.

The study was aimed at examining whether an oxygen inhibition layer is required for bonding a repairing to a pre-existing composite, and to determine the time required for free radicals within a composite substrate to decay to the extent that the composite repair strength drops significantly. Ten slabs of Gradia Direct Anterior (GC Corp.) were divided into (1) control group: an interfacial oxygen inhibition layer was created by applying and light-curing two layers of bonding resin (D/E Resin, Bisco) to the slabs surface in atmospheric air; (2) experimental group: the absence of an interfacial oxygen inhibition layer was obtained by light-curing the second bonding resin layer in a nitrogen atmosphere. After 1 and 2 h, 1, 14, and 30 days of air storage, a composite repair was layered over the bonding resin. Microtensile bond strengths were measured and statistically analyzed. The curing atmosphere was not a significant factor for bond strength (p = 0.82), and time and curing atmosphere-time interaction were significant (p < 0.001). The 30 day-strengths were the lowest (p < 0.05). An oxygen-inhibited layer is not initially required for bonding to resin composite, and it takes more than 14 days before the bond strength between a pre-existing and a fresh composite drops.

Biomechanical Phenomena↗