PubMed Health⌕ Search

PubMed · 15723951

Mandibular angle fractures and noncompression plating techniques.

Abstract

The source did not provide an abstract. Follow the original record for more information.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Andrew H Murr. 2005. Mandibular angle fractures and noncompression plating techniques.. https://doi.org/10.1001/archotol.131.2.166

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Geometry of human ribs pertinent to orthopedic chest-wall reconstruction.

Orthopedic reconstruction of blunt chest trauma can aid restoration of pulmonary function to reduce the mortality associated with serial rib fractures and flail chest injuries. Contemporary chest wall reconstruction requires contouring of generic plates to the complex surface geometry of ribs. This study established a biometric foundation to generate specialized, anatomically contoured osteosynthesis hardware for rib fracture fixation. On human cadaveric ribs three through nine, the surface geometry pertinent to anatomically conforming osteosynthesis plates was characterized by quantifying the apparent rib curvature C(A), the longitudinal twist alpha(LT) along the diaphysis, and the unrolled curvature C(U). In addition, the rib cross-sectional geometry pertinent to intramedullary fixation strategies was characterized in terms of cross-section height, width, area, and cortex thickness. The rib surface exhibited a curvature C(A) ranging from 3.8 m(-1) in the anteromedial section of rib seven to 17.3 m(-1) in the posterior section of rib three. All ribs had in common a longitudinal twist alpha(LT), ranging from 41-60 degrees. The unrolled curvature C(U) decreased gradually from ribs three to five, and increased gradually with reversed orientation from rib six to nine. The cross-sectional area remained constant along the rib diaphysis. However, the medullary canal increased in size from 29.9 mm(2) posteriorly to 41.2 mm(2) in anterior rib segments. Results of this biometric rib characterization describe a novel strategy for intraoperative plate contouring and provide a foundation for the development of specialized rib osteosynthesis strategies.

Bone Plates↗

Assessment of carbon fibre composite fracture fixation plate using finite element analysis.

In the internal fixation of fractured bone by means of bone-plates fastened to the bone on its tensile surface, an on-going concern has been the excessive stress shielding of the bone by the excessively-stiff stainless-steel plate. The compressive stress shielding at the fracture-interface immediately after fracture-fixation delays callus formation and bone healing. Likewise, the tensile stress shielding in the layer of bone underneath the plate can cause osteoporosis and decrease in tensile strength of this layer. In this study a novel forearm internal fracture fixation plate made from short carbon fibre reinforced plastic (CFRP) was used in an attempt to address the problem. Accordingly, it has been possible to analyse the stress distribution in the composite plates using finite-element modelling. A three-dimensional, quarter-symmetric finite element model was generated for the plate system. The stress state in the underlying bone was examined for several loading conditions. Based on the analytical results the composite plate system is likely to reduce stress-shielding effects at the fracture site when subjected to bending and torsional loads. The design of the plate was further optimised by reducing the width around the innermost holes.

Bone Plates↗