Direct-push hydrostratigraphic profiling: coupling electrical logging and slug tests.

Abstract

Spatial variations in hydraulic conductivity (K) can significantly affect the transport of contaminants in ground water. Conventional field methods, however, rarely provide a description of these variations at the level of detail necessary for reliable transport predictions and effective remediation designs. A direct-push (DP) method, hydrostratigraphic profiling, has been developed to characterize the spatial variability of both electrical conductivity (EC) and hydraulic conductivity in unconsolidated formations in a cost-effective manner. This method couples a dual-rod approach for performing slug tests in DP equipment with high-resolution EC logging. The method was evaluated at an extensively studied site in the Kansas River floodplain. A series of profiles was performed on a surface grid, resulting in a detailed depiction of the three-dimensional distribution of EC and K. Good agreement was found between K estimates obtained from this approach and those obtained using other methods. The results of the field evaluation indicate that DP hydrostratigraphic profiling is a promising method for obtaining detailed information about spatial variations in subsurface properties without the need for permanent wells.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Stephen M Sellwood, John M Healey, Steffen Birk, James J Butler. Direct-push hydrostratigraphic profiling: coupling electrical logging and slug tests.. https://doi.org/10.1111/j.1745-6584.2005.tb02282.x

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Identifying and counting point defects in carbon nanotubes.

The prevailing conception of carbon nanotubes and particularly single-walled carbon nanotubes (SWNTs) continues to be one of perfectly crystalline wires. Here, we demonstrate a selective electrochemical method that labels point defects and makes them easily visible for quantitative analysis. High-quality SWNTs are confirmed to contain one defect per 4 microm on average, with a distribution weighted towards areas of SWNT curvature. Although this defect density compares favourably to high-quality, silicon single-crystals, the presence of a single defect can have tremendous electronic effects in one-dimensional conductors such as SWNTs. We demonstrate a one-to-one correspondence between chemically active point defects and sites of local electronic sensitivity in SWNT circuits, confirming the expectation that individual defects may be critical to understanding and controlling variability, noise and chemical sensitivity in SWNT electronic devices. By varying the SWNT synthesis technique, we further show that the defect spacing can be varied over orders of magnitude. The ability to detect and analyse point defects, especially at very low concentrations, indicates the promise of this technique for quantitative process analysis, especially in nanoelectronics development.

Electric Conductivity↗

Ionic conduction in Zn3(PO4)2.4H2O enables efficient discharge of the zinc anode in serum.

Batteries contain corrosive or reactive components necessitating containment in a case, setting a limit to their miniaturization. Miniature, small-capacity batteries could power medical sensors in the body, for example sensing glucose for diabetes management. A miniature, case-less Zn-Ag/AgCl battery would consist merely of a zinc anode and a bioinert gel-coated Ag/AgCl cathode, if both operated efficiently in the interstitial fluid. Such a battery has not previously been built, primarily because of rapid corrosion of Zn. We show that the corrosion of zinc is significantly reduced by growth of Zn2+-ion-conducting, O2-impermeable, hopeite [Zn3(PO4)2.4H2O] lamellae on the Nafion-coated Zn anode. The hopeite lamellae allow discharge of the Zn anodes over three weeks at 86% current efficiency in physiological buffer and at 60% efficiency over two weeks in serum. The Zn|physiological buffer|Ag/AgCl cell operates at 1.00 V at 13 muA cm-2 and at 0.94 V at 0.2 mA cm-2 anodic current density.

Electric Conductivity↗

Charge recombination via intercolumnar electron tunneling through the lipid-like mantle of discotic hexa-alkyl-hexa-peri-hexabenzocoronenes.

The recombination of the mobile charge carriers formed in pulse-ionized hexa-alkyl-substituted hexa-peri-hexabenzocoronenes occurs mainly via intercolumnar electron tunneling through the intervening hydrocarbon mantle. This is evidenced as a dramatic increase in the time scale of the decay of the radiation-induced conductivity from a few hundred nanoseconds to close to a millisecond as the peripheral alkyl substituents increase in size from 8 to 24 carbon atoms with corresponding disk diameters, D, from 23.4 to 36.6 A. The decay kinetics are a function only of the total number of peripheral carbon atoms with no evidence for specific effects of chain branching. The 1/e decay time, tau(e), increases exponentially with D according to tau(e) = tau(e)(0) exp(betaD) with tau(e)(0) = 48 fs and beta = 0.63 A(-1). Taking into account the tilted columnar configuration of the molecules in the solid phase leads to a beta value of ca. 0.8 A(-1) for the distance dependence of intercolumnar electron tunneling. In contrast to the orders of magnitude changes in the time scale for intercolumnar charge recombination, the intracolumnar charge hopping times vary by only a factor of 4, between 40 and 160 fs, with no systematic dependence on the nature of the alkyl substituents. On the basis of the results, the time scale estimated for electron tunneling across a 40 A thick lipid membrane is estimated to be close to 1 ms.

Electric Conductivity↗