A reference architecture for telemonitoring.

Abstract

The Telecare Interactive Continuous Monitoring System exploits GPRS to provide an ambulatory device that monitors selected vital signs on a continuous basis. Alarms are sent when parameters fall outside preset limits, and accompanying physiological data may also be transmitted. The always-connected property of GPRS allows continuous interactive control of the device and its sensors, permitting changes to monitoring parameters or even enabling continuous monitoring of a sensor in emergency. A new personal area network (PAN) has been developed to support short-range wireless connection to sensors worn on the body including ECG and finger worn SpO2. Most notable is use of ultra low radio frequency to reduce power to minimum. The system has been designed to use a hierarchical architecture for sensors and "derived" signals, such as HR from ECG, so that each can be independently controlled and managed. Sensors are treated as objects, and functions are defined to control aspects of behaviour. These are refined in order to define a generic set of abstract functions to handle the majority of functions, leaving a minimum of sensor specific commands. The intention is to define a reference architecture in order to research the functionality and system architecture of a telemonitoring system. The Telecare project is funded through a grant from the European Commission (IST programme).

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Malcolm Clarke. 2004. A reference architecture for telemonitoring.. https://pubmed.ncbi.nlm.nih.gov/15747944/

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Scanning path optimization for ultrasound surgery.

One of the problems in ultrasound surgery is the long treatment times when large tumour volumes are sonicated. Large tumours are usually treated by scanning the tumour volume using a sequence of individual focus points. During the scanning, it is possible that surrounding healthy tissue suffers from undesired temperature rise. The selection of the scanning path so that the tumour volume is treated as fast as possible while temperature rise in healthy tissue is minimized would increase the efficiency of ultrasound surgery. The main purpose of this paper is to develop a computationally efficient method which optimizes the scanning path. The optimization algorithm is based on the minimum time formulation of the optimal control theory. The developed algorithm uses quadratic cost criteria to obtain the desired thermal dose in the tumour region. The derived method is evaluated with numerical simulations in 3D which are applied to ultrasound surgery of the breast in simplified geometry. Results from the simulations show that the treatment time as well as the total applied energy can be decreased from 16% to 43% as compared to standard sonication. The robustness of the optimized scanning path is studied by varying the perfusion and absorption in the tumour region.

Body Temperature↗

Temperature evolution on human teeth root surface after diode laser assisted endodontic treatment.

The thermal rise threshold of an 810-nm semi-conductor diode laser on the root surface when used in root canals in vitro for laser assisted root canal treatment is investigated in this study. A total of 50 human single-rooted extracted teeth were included. For this study, the canals were enlarged up to an apical size of ISO#50 file. Laser irradiation was performed with six different settings. Specimens were irradiated at 0.6-1 W output power at the distal end of the fiber and about 1-1.5 W output power in the continuous mode (CW) as two groups. In the third group, 0.6-1 W output power, 10 ms pulse length (PL) and 10 ms interval duration (ID) were selected. In three other groups 1-1.5 W output power were used with different PL and ID as following: PL 10 and ID 10 ms, PL 10 and ID 20 ms and PL 20 and ID 20 ms. The total irradiation time was from 5 to 20 s per canal with a 200 mum in diameter and 25 mm long tip. After laser treatment, the temperature changes at the outer root surface were registered by means of NiCr-Ni measuring sensors and a T 202 thermometer. The safe temperature threshold for applying this diode laser in root canal is considered as 7 degrees C increase. To avoid increasing the temperature changes at the outer root surface related to this threshold, following total irradiation times were found: 0.6-1 W output power (10 ms PL/10 ms ID): 20 s (s), 1-1.5 W output power (10 ms/10 ms and 20 ms/20 ms): 15 s, 0.6-1 W output power CW and 1-1.5 W output power (20 ms PL/10 ms ID): 10 s and 1-1.5 W output power CW: 5 s. In the first three groups, 5 s irradiation and 5 s rest period avoided a temperature increase above the threshold of 7 degrees C).

Body Temperature↗

Surface and intra-pulpal temperature rises during tooth bleaching: an in vitro study.

OBJECTIVE: To measure the surface and intra-pulpal temperature increases in vitro on upper and lower anterior teeth during tooth whitening procedures. METHOD: A thermocouple was used to measure the temperature increase on the surface of an extracted upper central incisor tooth. Intra-pulpal temperature readings were made on upper and lower central incisors, lateral incisors and canines. Four lamps recommended for tooth bleaching were tested; a plasma arc lamp, a xenon-halogen lamp, a standard halogen lamp and a diode laser lamp. Temperature measurements were made with and without the bleaching agent present on the labial tooth surface. RESULTS: The increase in surface temperature readings ranged from 0.44 degrees C (luma arch) to 86.3 degrees C (laser) with no bleaching gel present. Intra-pulpal temperature increases ranged from 0.30 degrees C to 15.96 degrees C. The presence of the bleaching gel reduced temperature increases seen at the tooth surface and within the pulp. CONCLUSIONS: The increase in the intrapulpal temperature with most bleaching lamps was below the critical threshold of a 5.50 degrees C increase thought to produce irreversible pulpal damage. The only lamp that produced an intrapulpal temperature increase above this threshold was the laser-based lamp and caution is advised when using this equipment.

Body Temperature↗