A TCP-NTCP estimation module using DVHs and known radiobiological models and parameter sets.

Abstract

Radiotherapy treatment plan evaluation relies on an implicit estimation of the tumor control probability (TCP) and normal tissue complication probability (NTCP) arising from a given dose distribution. A potential application of radiobiological modeling to radiotherapy is the ranking of treatment plans via a more explicit determination of TCP and NTCP values. Although the limited predictive capabilities of current radiobiological models prevent their use as a primary evaluative tool, radiobiological modeling predictions may still be a valuable complement to clinical experience. A convenient computational module has been developed for estimating the TCP and the NTCP arising from a dose distribution calculated by a treatment planning system, and characterized by differential (frequency) dose-volume histograms (DDVHs). The radiobiological models included in the module are sigmoidal dose response and Critical Volume NTCP models, a Poisson TCP model, and a TCP model incorporating radiobiological parameters describing linear-quadratic cell kill and repopulation. A number of sets of parameter values for the different models have been gathered in databases. The estimated parameters characterize the radiation response of several different normal tissues and tumor types. The system also allows input and storage of parameters by the user, which is particularly useful because of the rapidly increasing number of parameter estimates available in the literature. Potential applications of the system include the following: comparing radiobiological predictions of outcome for different treatment plans or types of treatment; comparing the number of observed outcomes for a cohort of patient DVHs to the predicted number of outcomes based on different models/parameter sets; and testing of the sensitivity of model predictions to uncertainties in the parameter values. The module thus helps to amalgamate and make more accessible current radiobiological modeling knowledge, and may serve as a useful aid in the prospective and retrospective analysis of radiotherapy treatment plans.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Brad Warkentin, Pavel Stavrev, Nadia Stavreva, Colin Field, B Gino Fallone. 2004-01-01. A TCP-NTCP estimation module using DVHs and known radiobiological models and parameter sets.. https://doi.org/10.1120/jacmp.v5i1.1970

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Patient dose measurements in diagnostic radiology procedures in Korea.

This study is the first nationwide investigation aimed at estimating the patient dose for radiographic examinations in Korea including gastrointestinal studies, computed tomography and mammography. The survey data from 161 hospitals and the dose data from 32 hospitals were analysed. The third quartile entrance surface dose, dose area product (DAP), weighted CT dose index (CTDIw) and mean glandular dose (MGD) were reported. All the estimated doses were less than the stated International Atomic Energy Agency (IAEA) reference levels for radiographic examinations. However, DAPs for the fluoroscopic examinations had higher dose values than the IAEA reference levels. In addition, the CTDIw and MGD were lower than the IAEA reference levels.

Body Burden↗

The study of new calibration features in the Harshaw TLD system.

The Harshaw TLD system has three key calibration procedures: the Reader, the Dosemeter and the Algorithm. These functions must be properly calibrated for the system to achieve the optimum results. For the conventional reader and dosemeter calibration, Harshaw TLD recommends a pre-fade and a post-fade of 24-48 h when calibrating the system for LiF:Mg,Ti type dosemeter. It is also recommended that keeping the fade time consistent is important to maintain the quality of the system performance. In recent years, new calibration features have been introduced into the Harshaw TLD models 6600 and 8800 operating systems. These new features are Auto Calibration, Auto QC and Auto Blank, and they give the user the ability to set up the clear-expose-read process to be performed automatically in a sequence for each dosemeter. This saves processing time and keeps the fade time the same. However, since the fade time is near zero, will it affect the TLD system calibration factors? What should the user expect? This paper presents a study of the effect of Auto Calibration/Auto QC to the TLD operation.

Body Burden↗

Proton and photon absorbed-dose conversion coefficients for embryo and foetus from top-down irradiation geometry.

Absorbed-dose conversion coefficients are calculated for the embryo of 8 weeks and the foetus of 3, 6 or 9 months when the mother's body is exposed to protons and photons from top-down (TOP) direction. It provides data sets in addition to other standard irradiation geometries published previously. The TOP-irradiation geometry is considered here, because high-energy particles are often peaked from the TOP direction onboard aircrafts. The results show that absorbed-doses from high-energy particles could be underestimated significantly if isotropic (ISO) irradiation geometry is assumed. For protons of 100 GeV, absorbed-doses from TOP irradiation are approximately 2.3-2.9 times higher than the doses from ISO irradiation for different foetal ages. For 10 GeV photons, foetal doses from TOP irradiation are approximately 6.8-12 times higher than the doses from ISO irradiation. The coefficients from TOP-irradiation geometry are given in wide energy ranges, from 100 MeV to 100 GeV for protons and from 50 keV to 10 GeV for photons. They can, therefore, be used in various applications whenever exposure from the TOP-irradiation direction is concerned.

Body Burden↗