PubMed Health⌕ Search

PubMed · 15759582

Implantable cardiac pacemaker electromagnetic compatibility testing in a novel security system simulator.

Abstract

This paper describes a novel simulator to perform electromagnetic compatibility (EMC) tests for active implantable medical devices (AIMDs) with electromagnetic fields emitted by security systems. The security system simulator was developed in response to over 100 incident reports over 17 years related to the interference of AIMD's with security systems and the lack of a standardized test method. The simulator was evaluated regarding field homogeneity, signal distortion, and maximum magnetic field strength levels. Small three-axis probes and a three-axis scanning system were designed to determine the spatial and temporal characteristics of the fields emitted by 12 different types of walk through metal detectors (WTMDs). Tests were performed on four implanted pacemakers with a saline phantom and correlated to a newly developed test method performed "in air" (without the phantom). Comparison of the simulator thresholds with tests performed in real WTMDs showed that the simulator is able to mimic the pacemaker interference. The interference thresholds found in the simulator indicate that pulsed magnetic fields are more likely to cause interference in pacemakers than sinusoidal fields. The security system simulator will help biomedical engineers, manufacturers of medical devices, and manufacturers of security systems to identify incompatible combinations of WTMDs and AIMDs early in the development stage.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Wolfgang Kainz, Jon P Casamento, Paul S Ruggera, Dulciana D Chan, Donald M Witters. 2005. Implantable cardiac pacemaker electromagnetic compatibility testing in a novel security system simulator.. https://doi.org/10.1109/tbme.2004.843293

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Development and evaluation of the electromagnetic hypersensitivity questionnaire.

Electromagnetic hypersensitivity (EHS) syndrome is usually defined as a condition where an individual experiences adverse health effects that he or she believes is due to exposure to objects that emit electromagnetic fields. The aim of this study was to develop a questionnaire that would identify the key symptoms associated with EHS and determine how often these symptoms occur in the general population of the United Kingdom. In the pilot study, an EHS questionnaire was developed and tested. In Study 1 the EHS questionnaire was revised and sent to a randomly selected sample of 20,000 people. Principal components analysis of the symptoms resulted in eight subscales: neurovegetative, skin, auditory, headache, cardiorespiratory, cold related, locomotor, and allergy related symptoms. Study 2 established the validity of the questionnaire in that EHS individuals showed a higher severity of symptoms on all subscales compared to the control group. The two key results of this study were the development of a scale that provides an index of the type and intensity of symptoms commonly experienced by people believing themselves to be EHS and a screening tool that researchers can use to pre-select the most sensitive individuals to take part in their research.

Electromagnetic Fields↗

Extremely low frequency weak magnetic fields enhance resistance of NN tobacco plants to tobacco mosaic virus and elicit stress-related biochemical activities.

Increasing evidence has accumulated concerning the biological effects of extremely low frequency magnetic fields (ELF-MFs) in different plant models. In the present study, effects of ELF-MFs in tobacco plants reacting to tobacco mosaic virus (TMV) with a hypersensitive response (HR) were evaluated. Plants were exposed for 8 or 24 h (either before or after TMV inoculation) to a static MF, at either -17 or 13 microT, combined with a 10 Hz sinusoidal MF with different intensities (25.6 or 28.9 microT). The working variables were the area and number of hypersensitive lesions in leaves. Following ELF-MFs exposure, an increased resistance was detected, particularly after an 8-h treatment, as shown by the decrease in lesion area and number. Moreover, two enzyme activities involved in resistance mechanisms were analyzed: ornithine decarboxylase (ODC) and phenylalanine ammonia-lyase (PAL). Uninoculated leaves previously exposed to ELF-MFs in general showed a significant increase relative to controls in ODC and PAL activities, in particular for 13 microT static MF plus 28.9 microT, 10 Hz sinusoidal MF (24 h) treatment. In conclusion, ELF-MFs seem to influence the HR of tobacco to TMV, as shown by the increased resistance and changes in ODC and PAL activities, indicating the reliability of the present plant model in the study of bioelectromagnetic interactions.

Electromagnetic Fields↗