Sacral nerve stimulation for faecal incontinence.

Abstract

Faecal incontinence is a common problem. Conservative measures are effective in a significant proportion of patients. Failure of conservative management has until recently meant recourse to surgical intervention. Surgical treatment is often associated with disappointing results. Recently, sacral nerve stimulation (SNS) has been developed as a minimally invasive, effective technique for idiopathic and acquired faecal incontinence. The technique uses chronic low-level electrical stimulation of the sacral nerves, or neuromodulation, to produce a clinically beneficial effect on the distal colon and rectum, the pelvic floor and the anal sphincter complex. SNS is a 2-stage procedure: a diagnostic stage - temporary percutaneous nerve evaluation (PNE), and a therapeutic stage - permanent SNS. The predictive value of PNE is high, and the surgical trauma and morbidity of both procedures extremely low. The technique has been adapted from its original application in urinary dysfunction. It is almost impossible to produce level 1 evidence for this type of intervention; however, the results are superior to other interventions. Patient selection criteria are evolving, but there is a growing body of evidence that supports its use as first-line treatment for faecal incontinence in patients where conservative measures have failed.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Stephen H Pillinger, Angela Gardiner, Graeme S Duthie. 2005-03-09. Sacral nerve stimulation for faecal incontinence.. https://doi.org/10.1159/000084344

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Modeling biological motor control for human locomotion with functional electrical stimulation.

This paper develops a novel control system for functional electrical stimulation (FES) locomotion, which aims to generate normal locomotion for paraplegics via FES. It explores the possibility of applying ideas from biology to engineering. The neural control mechanism of the biological motor system, the central pattern generator, has been adopted in the control system design. Some artificial control techniques such as neural network control, fuzzy logic, control and impedance control are incorporated to refine the control performance. Several types of sensory feedback are integrated to endow this control system with an adaptive ability. A musculoskeletal model with 7 segments and 18 muscles is constructed for the simulation study. Satisfactory simulation results are achieved under this FES control system, which indicates a promising technique for the potential application of FES locomotion in future.

Electric Stimulation Therapy↗

Complications and troubleshooting of two-stage sacral neuromodulation therapy: a single-institution experience.

OBJECTIVES: With the increasing use of sacral neuromodulation therapy, urologists are faced with postimplantation challenges. The purpose of this study was to identify these events and their causes and management in our large single-institution experience. METHODS: From July 2002 to September 2004, all patients who underwent sacral neuromodulation therapy for refractory bladder conditions were identified. Their medical records were retrospectively evaluated for history, operative intervention, and programming visits. Events after implantation of the implantable pulse generator (IPG) unit were noted. The evaluation, troubleshooting, management, and resolution of events at the last follow-up visit were extracted. RESULTS: A total of 214 patients underwent sacral neuromodulation therapy at our institution. The mean patient age was 53.5 +/- 15.4 years. Of the 214 patients, 161 underwent IPG implantation during a mean follow-up period of 16 months (range 5 to 30). The second-stage explantation and revision rate was 10.5% and 16.1%, respectively. The indications for explantation were infection (8 of 17) and failure to maintain a response (9 of 17). Revisions were done for decreases in response with abnormal (12 of 26) or normal (5 of 26) impedance measurements, IPG site discomfort (4 of 26), draining sinus at the IPG site (4 of 26), and lead migration (1 of 26). Equalization of impedance measurements was the most commonly observed impedance abnormality. These were managed by drying fluid from the connection in 4 patients and lead change in the rest. CONCLUSIONS: After IPG implantation, a decline in response may occur. Although some were explanted, most were revised, with most of the revisions functional on follow-up. Familiarity with impedance evaluation and development of algorithms for postimplant management are essential for troubleshooting and maintenance of the device.

Electric Stimulation Therapy↗