PubMed Health⌕ Search

PubMed · 15789585

Is the diaphragm motion probability density function normally distributed?

Abstract

During radiotherapy treatment planning, the margins given to the clinical target volume to form the planning target volume accounts for internal motion and set-up error. Most margin formulas assume that the underlying distributions are independent and normal. Clinical data suggests that the set-up error probability density function (pdf) can be considered to have an approximately normal distribution. However, there is evidence that internal motion does not have a normal distribution. Thus, in general, a convolution of the two pdfs should be performed to determine the total geometric error. The goals of this article were to (1) determine if the internal motion pdf due to respiration can be characterized using a normal distribution, and (2) if not, determine if the total geometric uncertainty for combining internal motion and set-up error can be characterized by a normal distribution. Sixty fluoroscopy diaphragm motion data sets were obtained using three breathing training types: free breathing, audio instruction, and visual feedback. Diaphragm motion was used as a surrogate for liver and lung cancer motion. The data were analyzed with normality tests in the following groups: (1) single motion measurements, (2) combined motion measurements for each patient, and (3) combined motion measurements for all patients. Following this analysis, the diaphragm motion pdfs were convolved with a set-up error pdf, and the standard deviation of the set-up error pdf at which the total geometric error pdf became normal was determined. At set-up error standard deviation values of at least 0.27 and 0.1 cm for free breathing, 0.57 and 0.42 cm for audio instruction, and 0.55 and 0 cm for visual feedback, for single motion measurements and combined motion measurements for each patient, respectively, total geometric error pdfs became approximately normal. When the motion measurements for all the patients were combined, diaphragm motion pdfs were approximately normal for all feedback types. Therefore, for treatment planning purposes in the absence of individual patient measurements, the diaphragm motion pdf can be considered an approximately normal distribution. However, care should be taken when determining a margin based on individual patients measurements as the total geometric error will, in general, not be normally distributed.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

R George, P J Keall, V R Kini, S S Vedam, V Ramakrishnan, R Mohan. 2005. Is the diaphragm motion probability density function normally distributed?. https://doi.org/10.1118/1.1845031

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Striping artifact removal in VisiumHD data through nuclear counts modeling.

MOTIVATION: 10x Genomics VisiumHD enables spatial transcriptomics at 2 µm × 2 µm resolution but exhibits slide-specific, non-periodic striping artifacts due to lane-width variability. These multiplicative row/column effects distort bin total counts and can bias downstream analyses. The state-of-the-art destriping approach is the normalization procedure used as a preprocessing step in bin2cell; it applies sequential high-quantile row- then column-wise normalization, which is asymmetric and can introduce edge effects/macro-stripes and distortions of large-scale total-count structure. RESULTS: We propose a statistical destriping approach that leverages nuclei segmentation from the co-registered H&E image. Assuming transcript abundance is constant within each nucleus, we model bin counts with a negative binomial distribution whose mean is a product of a nucleus-specific concentration and row- and column-specific stripe-factors reflecting lane-width variation. We fit all parameters in a generalized linear modeling framework with cross-validated regularization on stripe-factors and iterative dispersion estimation, and use the fitted parameters to correct the observed counts into a destriped image. On synthetic data with known ground truth, our method improves stripe-factor estimation accuracy and reduces error in corrected counts relative to bin2cell and bin2cell-derived baselines. Across four public VisiumHD slides, it consistently lowers striping intensity while substantially better preserving biological signal present in the large-scale global count structure and avoiding the artifacts introduced by other methods. AVAILABILITY AND IMPLEMENTATION: All source code and links to publicly available data used for this study are available at https://github.com/paolamalsot/destriping-GLM.

Artifacts↗

Impairment of echocardiographic acoustic window caused by breast implants.

Cosmetic breast implants are increasing in popularity. The presence of a breast implant overlying the anterior mediastinal space as a cause of impairment of the echocardiographic acoustic window has not been described previously. Here, we report three cases with significant impairment of echocardiographic acoustic window caused by breast implants. Clinicians should be aware of this interference and women should be informed of this dilemma before considering this cosmetic surgery.

Artifacts↗