Detection and prevention of medication errors using real-time bedside nurse charting.

Abstract

OBJECTIVE: Charting systems with decision support have been developed to assist with medication charting, but many of the features of these programs are not properly used in their clinical application. An analysis of medication error reports at LDS Hospital revealed the occurrence of errors that should have been detected and prevented by decision support features if real-time entry at the bedside had taken place. The aim of this study was to increase the real-time bedside charting behavior of nurses. DESIGN: A quasiexperimental before and after design was used. The study took place in two 40-bed surgical units, one of which served as the study unit, the other as control unit. The study unit received educational intervention about error avoidance through real-time bedside charting, and 12 weeks of monitoring and performance feedback. The real-time and bedside charting rates for the study and control units were measured before and after the intervention. RESULTS: Before the intervention on the study unit, the real-time charting rate was 59% and the bedside rate was 40%. At the conclusion of a 12-week intervention period, the real-time rate increased to 73% and the bedside rate increased to 63%. Postintervention real-time rates were 75% after eight weeks and remained at 75% after one year. Equivalent control unit real-time rates varied from 53% to 57%, and bedside rates varied from 34% to 44% during the same intervals. CONCLUSION: Targeted educational intervention and monitored feedback yielded measurable improvements in the effective use of the computerized medication charting system and must be an ongoing process.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Nancy C Nelson, R Scott Evans, Matthew H Samore, Reed M Gardner. 2005-03-31. Detection and prevention of medication errors using real-time bedside nurse charting.. https://doi.org/10.1197/jamia.m1692

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Miniature near-infrared dual-axes confocal microscope utilizing a two-dimensional microelectromechanical systems scanner.

The first, to our knowledge, miniature dual-axes confocal microscope has been developed, with an outer diameter of 10 mm, for subsurface imaging of biological tissues with 5-7 microm resolution. Depth-resolved en face images are obtained at 30 frames per second, with a field of view of 800 x 100 microm, by employing a two-dimensional scanning microelectromechanical systems mirror. Reflectance and fluorescence images are obtained with a laser source at 785 nm, demonstrating the ability to perform real-time optical biopsy.

Computer Systems↗

Proposal for fulfilling strategic objectives of the U.S. Roadmap for national action on clinical decision support through a service-oriented architecture leveraging HL7 services.

Despite their demonstrated effectiveness, clinical decision support (CDS) systems are not widely used within the U.S. The Roadmap for National Action on Clinical Decision Support, published in June 2006 by the American Medical Informatics Association, identifies six strategic objectives for achieving widespread adoption of effective CDS capabilities. In this manuscript, we propose a Service-Oriented Architecture (SOA) for CDS that facilitates achievement of these six objectives. Within the proposed framework, CDS capabilities are implemented through the orchestration of independent software services whose interfaces are being standardized by Health Level 7 and the Object Management Group through their joint Healthcare Services Specification Project (HSSP). Core services within this framework include the HSSP Decision Support Service, the HSSP Common Terminology Service, and the HSSP Retrieve, Locate, and Update Service. Our experiences, and those of others, indicate that the proposed SOA approach to CDS could enable the widespread adoption of effective CDS within the U.S. health care system.

Computer Systems↗

Imaging tumour motion for radiotherapy planning using MRI.

Novel technology has made dynamic magnetic resonance imaging (MRI) of lung motion and lung tumour mobility during continuous respiration feasible. This might be beneficial for planning of radiotherapy of lung tumours, especially when using high precision techniques. This paper describes the recent developments to analyze and visualize pulmonary nodules during continuous respiration using MRI. Besides recent dynamic two-dimensional approaches to quantify motion of pulmonary nodules during respiration novel three-dimensional techniques are presented. Beyond good correlation to pulmonary function tests MRI also provides regional information about differences between tumour-bearing and non-tumour bearing lung and the restrictive effects of radiotherapy as well as the compensation by the contralateral lung.

Computer Systems↗