PubMed Health⌕ Search

PubMed · 15807389

Vascular wall shear stress: basic principles and methods.

Abstract

The source did not provide an abstract. Follow the original record for more information.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Theodoros G Papaioannou, Christodoulos Stefanadis. Vascular wall shear stress: basic principles and methods.. https://pubmed.ncbi.nlm.nih.gov/15807389/

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Three dimensional finite element analysis of the pediatric lumbar spine. Part II: biomechanical change as the initiating factor for pediatric isthmic spondylolisthesis at the growth plate.

A non-linear 3-dimensional finite element pediatric lumbar spine model with vertebral growth plate and apophyseal bony ring was developed. Lumbar spondylolysis was simulated in the model. The Von Mises stresses in the structures surrounding the vertebral growth plate, including apophyseal bony ring and osseous endplate were calculated in various loading modes. Instantaneous axis of rotation (IAR) path from flexion to extension was also analyzed. The results were compared with those of the intact model and the literature. The IAR path was at the posterior disc-endplate space of the lower vertebra in the intact spine, and moved cranially towards the upper-posterior disc space in the lytic spine. This was in agreement with in vivo radiological data by Sakamaki et al. [19]. During various loading modes, stresses in the spondylolytic pediatric model were higher than that of the intact model; ranging from 1.1 to 6.0 times, with the highest value in extension at the growth plate. In conclusion, FE models indicate that stress concentrations in the lytic model increase at the growth plate which may lead to physis stress fracture leading to spondylolisthesis.

Biomechanical Phenomena↗

Importance of individual rods and plates in the assessment of bone quality and their contribution to bone stiffness.

UNLABELLED: Local morphometry based on the assessment of individual rods and plates was applied to 42 human vertebral trabecular bone samples. Results showed that multiple linear regression models based on local morphometry as a measure for bone microstructure helped improving our understanding of the role of local structural changes in the determination of bone stiffness as assessed from direct and computational biomechanics. INTRODUCTION: In a recent study, we proposed a method for local morphometry of trabecular bone, i.e., morphometry as applied to individual rods and plates. In this study, we used this method to study the relative importance of local morphometry in the assessment of bone architecture and its relative contribution to the stiffness of human vertebral bone. MATERIALS AND METHODS: We extracted 42 human trabecular bone autopsies from nine intact spinal columns. The cylindrical samples were imaged with muCT to assess bone microstructure. From these images, global and local morphometric indices were derived and related to Young's modulus as assessed by experimental uniaxial compression testing (Emeas) and computational finite element analysis (EFE). RESULTS: We found the best single predictor for Young's modulus to be apparent bone volume density (BV/TV), which explained 89% of the variance in EFE when fitted with a power law. A multiple linear regression model combining mean trabecular spacing (Tb.Sp), mean slenderness of the rods ( ), and the relative amount of rod volume to total bone volume (Ro.BV/BV) was able to explain 90% of the variance in EFE. This model could not be improved by adding BV/TV as an independent variable. Furthermore, we found that mean trabecular thickness of the rods was significantly related to EFE (r2 = 0.42), whereas mean trabecular thickness of plates had no correlation to Young's modulus. Because the globally determined trabecular thickness does not discriminate between rods and plates, this index had only a poor predictive power for EFE (r2 = 0.09), showing the importance of local analysis of individual rods and plates. CONCLUSIONS: From these results, we conclude that models based on local morphometry help improving our understanding of the relative importance of local structural changes in the determination of the stiffness of bone. Separate analysis of individual rods and plates may help to better predict age and disease-related fractures as well as to shed new light on the effect of pharmaceutical intervention in the prevention of such fractures beyond BMD.

Biomechanical Phenomena↗

Mechanical properties of single living cells encapsulated in polyelectrolyte matrixes.

We have studied the mechanical properties of encapsulated Saccharomyces cerevisiae yeast cells by performing AFM force measurements. Single living cells have been coated through the alternate deposition of oppositely charged polyelectrolyte layers and mechanically trapped into a porous membrane. Coated and uncoated cells in presence/absence of bud scars, i.e. scars resulting from previous budding events, have been investigated. No significant differences between encapsulated and bare cells could be inferred from AFM topographs. On the other hand, investigation on the system elasticity through the acquisition and analysis of force curves allowed us to put in evidence the differences in the mechanical properties between the hybrid cell/polyelectrolyte system and the uncoated cells. Analysis of the curves contact region indicates that the polyelectrolyte coating increases the system rigidity. Quantitative evaluation of the cell rigidity through the Hertz-Sneddon model showed that coated cells are characterized by a Young's modulus higher than the value obtained for uncoated cells and similar to the value observed on the bud scar region of uncoated cells.

Biomechanical Phenomena↗