PURPOSE: To provide mathematical tools for selecting intraocular lens (IOL) power for normal eyes and for "odd" eyes, particularly after corneal refractive surgery. SETTING: Universitats-Augenklinik, Mainz, Germany. METHODS: First, IOL power is selected based on the radii and numerical eccentricity of the cornea, extracted from corneal topography in a consistent numerical model of the cornea. To fine-tune the result, the visual impression is simulated by blurred Landolt rings superimposed on the retinal receptor grid. The calculation uses numerical ray tracing of the whole pseudophakic eye comprising all monochromatic errors. The error contributions of the influencing parameters, such as anterior and posterior corneal shape and corneal thickness, are quantified in detail. The method is verified in IOL power selection for normal eyes and for eyes after corneal refractive surgery. RESULTS: The main difference between normal corneas and corneas after refractive surgery results from different asphericities. Normal corneas are prolate, with typical numerical eccentricities of 0.5, whereas corneas after laser surgery for myopia are oblate. This causes the main difference (hyperopic shift up to 2.0 diopters) in IOL power selection. Shifts in the posterior corneal radius and corneal thickness are of minor importance. CONCLUSION: Intraocular power selection after corneal refractive surgery should be based on all the information corneal topography provides.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Paul-Rolf Preussner, Jochen Wahl, Daniela Weitzel. 2005. Topography-based intraocular lens power selection.. https://doi.org/10.1016/j.jcrs.2004.09.016

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Profile of clear corneal cataract incisions demonstrated by ocular coherence tomography.

PURPOSE: To examine the profile of clear corneal cataract incisions in the living eye using optical coherence tomography (OCT). SETTING: Private practice, Eugene, Oregon, USA. METHODS: The Zeiss Visante OCT anterior segment imaging system was used to study the profile of clear corneal cataract incisions, all in senior citizens. The OCT images of the operative eye were taken on the first postoperative day approximately 24 hours after surgery. The OCT images of clear corneal incisions were compared with an OCT image of a control eye, incisions without stromal hydration, and previous drawings of clear corneal incisions. RESULTS: In the images, the clear corneal incisions had an arcuate configuration rather than a straight line configuration, as previously indicated. This architecture appears to add greater stability as a result of a tongue-and-groove-like fit of the floor to the roof of the incision as well as an incision that is longer than the chord length that had previously been measured. Other findings include that stromal swelling, which facilitates sealing of these incisions by the endothelial pump, lasted for at least 24 hours. CONCLUSIONS: Results indicate an incision in the plane of the cornea with a chord length of at least 2.0 mm provides advantageous architecture for adequate self-sealing. Proper clear corneal incision construction resulted in an incision architecture that seemed to have increased stability and added safety, contributing to an absence of endophthalmitis for more than 10 years and 9000 cases in a single practice.

Cataract Extraction↗

Teaching and assessing competence in cataract surgery.

PURPOSE OF REVIEW: To review recent literature regarding innovative techniques, methods of teaching and assessing competence and skill in cataract surgery. RECENT FINDINGS: The need for assessment of surgical competency and the requirement of wet lab facilities in ophthalmic training programs are being increasingly emphasized. Authors have proposed the use of standardized forms to collect objective and subjective data regarding the residents' surgical performance. Investigators have reported methods to improve visualization of cadaver and animal eyes for the wet lab, including the use of capsular dyes. The discussion of virtual reality as a teaching tool for surgical programs continues. Studies have proven that residents trained on a laparoscopic simulator outperformed nontrained residents during actual surgery for both surgical times and numbers of errors. Besides virtual reality systems, a program is being developed to separate the cognitive portion from the physical aspects of surgery. Another program couples surgical videos with three-dimensional animation to enhance the trainees' topographical understanding. SUMMARY: Proper assessment of surgical competency is becoming an important focus of training programs. The use of surgical data forms may assist in standardizing objective assessments. Virtual reality, cognitive curriculum and animation video programs can be helpful in improving residents' surgical performance.

Cataract Extraction↗