PubMed Health⌕ Search

PubMed · 15841737

Artifacts in 3D rotational angiography: an experimental study.

Abstract

PURPOSE: To investigate artifacts in three-dimensional rotational angiography (3D-RA) in an experimental model and to evaluate which parameters influence their distribution. MATERIAL AND METHODS: 3D-RA was carried out in a circular vessel phantom filled with contrast medium. Two different rotational angulations were used: 160 degrees causing 64 images and 180 degrees causing 90 or 120 images. The images were transferred to one workstation for reconstruction of axial slices and then to another workstation for 3D reconstructions. The 3D reconstructions were compared with standardized threshold settings. RESULTS: The artifacts occurred where the vessel had a longer path parallel to the rotation plane and became increasingly pronounced when the threshold level was raised. The artifacts decreased in size when rotation angle and number of projections were increased. CONCLUSION: The quality of the 3D reconstructions from RA was degraded by beam-hardening and sampling artifacts. The sampling artifacts were diminished by increasing both the rotation angle and the number of projections. The distortions in the 3D reconstructions caused by beam-hardening remain to be resolved. The threshold values also had a considerable influence on the 3D reconstructions.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

G Hagen, P G Lindgren, L Jangland, P Magnusson, A Magnusson. 2005. Artifacts in 3D rotational angiography: an experimental study.. https://doi.org/10.1080/02841850510012571

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Transhepatic vascular access for diagnostic and interventional procedures: techniques, outcome, and complications.

Early or multiple cardiac catheterizations may result in occlusion of the femoral veins prohibiting their use. The internal jugular or sub-clavian approach may be an appropriate alternative. However, these approaches may not be suitable in patients with surgical interruption of the superior vena cava. In other patients, they may not allow easy access to certain areas of the heart. The transhepatic approach is an important alternative route for performing cardiac catheterization and interventions. Depending on the planned procedure, it may be the preferred route to perform the cardiac catheterization even in the presence of patent femoral veins. The indications, technical details and potential complications of this approach are discussed.

Angiography↗

Embolization for a bleeding pelvic fracture in a patient with persistent sciatic artery.

Emergency embolization for a bleeding pelvic fracture was performed in a patient with persistent sciatic artery, a rare anatomic variation in which the internal iliac artery continues to the popliteal artery. Successful hemostasis was achieved without complications by means of selective catheterization into each branch of the internal iliac artery. Awareness of this unusual vascular anatomy is critically important to avoid serious complication of emergency embolization.

Angiography↗