PubMed Health⌕ Search

PubMed · 1584548

Flicker electroretinograms: a systems analytic approach.

Abstract

We observed multiple maxima and minima in the electroretinogram (ERG) first harmonics which varied as a function of adaptation level, mean illuminance, and modulation depth. Based on differences in response characteristics we identified a minimum of 3 parallel mechanisms operating at 3 frequency regions within the ERG: a low frequency region (less than 10 Hz), a midfrequency region (centered near 20 Hz), and a high frequency region (centered near 40 Hz). The low frequency region was observed both in dark- and light-adapted conditions, was basically linear, and showed nonlinear behavior only at high contrasts in either light or dark adaptation. It may be modeled as a low pass filter. The midfrequency region was clearly observed only above cone threshold, was nonlinear at low contrasts, and may be modeled as a linear filter followed by an essential nonlinearity. The high frequency region was observed under high levels of light adaptation and also was nonlinear at low contrast. It may be modeled also as a linear filter followed by an essential nonlinearity.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

J V Odom, D Reits, N Burgers, F C Riemslag. 1992. Flicker electroretinograms: a systems analytic approach.. https://doi.org/10.1097/00006324-199202000-00003

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

LED-generated multifocal ERG on- and off-responses in complete congenital stationary night blindness -- a case report.

We report on the application of a light emitting diode (LED) screen to elicit multifocal ERG on- and off-responses in a patient presenting with the complete type of congenital stationary night blindness (cCSNB): A 63-years old woman was diagnosed with cCSNB by means of standard ERG procedures and dark adaptometry. To confirm this diagnosis and to investigate topographical differences of on- and off-responses a multifocal approach employing long-duration stimuli was added. Results of mfERG-testing were averaged in three groups (a central area of 7.5 degrees , a ring area of 7.5-21.9 degrees and a peripheral ring of 21.9-31.1 degrees ). When compared to normal controls (n = 4) on-responses (P1-amplitudes) were severely reduced symmetrically at all eccentricities, while off-responses showed no reduction resulting in an increased off/on-ratio. Furthermore on-latencies of P1 were delayed symmetrically at all eccentricities, whereas off-latencies were normal. To our knowledge this is the first report of multifocal on- and off-responses in a CSNB-patient. Stimulus-generation with a LED-screen provides the advantage of a stable luminance during the long-duration on-phase.

Dark Adaptation↗

Is the spectacle lens jack-in-the-box phenomenon really due to the lenses?

The calculation of the extent of the ring scotoma around positive lenses, as conventionally taught to students of clinical optics, indicates that the scotoma is of a significant size. Using knife-edge lenses this study shows that the calculations are invalid due to the finite size of the eye's entrance pupil and in many instances the scotoma is shown not to exist. The effect noticed in clinical practice is probably largely due to the frame and the edging techniques used which add to the refractive scotoma which is present with high powered lenses, large apertures and/or small pupil sizes.

Dark Adaptation↗