PubMed Health⌕ Search

PubMed · 15859624

Interface for direct and continuous sample-matrix deposition onto a MALDI probe for polymer analysis by thermal field flow fractionation and off-line MALDI-MS.

Abstract

A simple interface based on an oscillating capillary nebulizer (OCN) is described for direct deposition of eluate from a thermal field-flow fractionation (ThFFF) system onto a matrix-assisted laser desorption/ionization (MALDI) probe. In this study, the polymer-containing eluent from the ThFFF system was mixed on-line with MALDI matrix solution and deposited directly onto a moving MALDI probe. The result was a continuous sample track representative of the fractionation process. Subsequent off-line MALDI-mass spectrometry analysis was performed in automated and manual modes. Polystyrene samples of broad polydispersity were used to characterize the overall system performance. The OCN interface is easy to build and operate without the use of heaters or high voltages and is compatible with any MALDI probe format.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Franco Basile, Galina E Kassalainen, S Kim Ratanathanawongs Williams. 2005-05-01. Interface for direct and continuous sample-matrix deposition onto a MALDI probe for polymer analysis by thermal field flow fractionation and off-line MALDI-MS.. https://doi.org/10.1021/ac048391d

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Reduction of end effect-induced zone broadening in field-flow fractionation channels.

A channel configuration for the elimination of end effects in field-flow fractionation (FFF) channels is simulated and demonstrated for a microfabricated FFF system. In field-flow fractionation, the carrier liquid and sample particles are transferred from a point injection to the full breadth of the rectangular channel using a triangular end piece at the inlet. The nonuniformity in streamline length generated by this end piece results in an increased instrument-related plate height. An additional contribution from the end piece at the outlet of the channel further increases the total band broadening. This paper presents a novel approach to minimize end-effect contributions to plate height by fabricating microstructures in the channel end sections to redistribute the flow streams and force streamline lengths to be more uniform. Numerical analysis of the flow profile and sample dispersion (including spreading of particles due to diffusion and advection) is carried out to investigate the optimized microstructure column size, shape, and placement in the end pieces. The configuration obtained from the numerical simulation results is used to design a prototype device. Experimental measurement of the plate heights for this prototype with an on-chip impedance-based detector shows marked improvement in performance due to the presence of the microstructures in comparison to conventional FFF channel geometry with an average 50% reduction in plate height. The redesigned inlet triangle results in a uniform transition of the point-injected sample into a thin and straight band across the width of the channel at the start of the rectangular section of the fractionation channel.

Fractionation, Field Flow↗

Effect of dissolution temperature on the structures of sodium hyaluronate by flow field-flow fractionation/multiangle light scattering.

Molecular weight distribution (MWD) and structural deformation of ultrahigh molecular weight (MW) sodium hylaluronate (10(5)-10(8) g/mol) were studied under different sample dissolution temperature conditions, using on-line flow field-flow fractionation (FlFFF) and multiangle light scattering (MALS). Sodium hyaluronate (NaHA) materials from sarcoma fluid have been studied by dissolving them in water at three different temperature conditions (5 degrees C, 50 degrees C, and 90 degrees C). Frit inlet asymmetrical flow field-flow fractionation (FI-AFlFFF), with field programming, was utilized for the separation of NaHA by MW, and on-line observation of light scattering of fractionated NaHA by MALS was performed in order to determine the MWD and molecular conformation. In these experiments, NaHA molecules exhibited an extended structure from a formerly rather compact geometry when the dissolving temperature was raised to 90 degrees C. This study also showed a clear difference in the MWD of NaHA when a preliminary filtration process was applied.

Fractionation, Field Flow↗

Different elution modes and field programming in gravitational field-flow fractionation: field programming using density and viscosity gradients.

In previous papers, several approaches to programming of the resulting force field in GFFF were described and investigated. The experiments were dealing with flow-velocity and channel thickness, i.e. factors influencing hydrodynamic lift forces (HLF). The potential of density and viscosity of carrier liquid for field programming was predicted and demonstrated by preliminary experiments. This work is devoted to experimental verification of the influence of carrier liquid density and viscosity. Several carrier liquid density and simultaneously viscosity gradients using water-methanol mixtures are in this work implemented in the separation of a model silica mixture. Working with the water-methanol gradients, one is not able to separate the influence of density from the contribution of viscosity. However, we found experimental conditions to show the isolated effect of carrier liquid density (two water-methanol mixtures of equal viscosity differing in their densities). In order to demonstrate the isolated effect of viscosity, we implemented in this work a new system of (hydroxypropyl)methyl cellulose (HPMC) carrier liquids. Three different HPMC compositions enabled to vary the viscosity more than two times at almost constant density. With increasing carrier liquid viscosity, the focusing and elevating trend was clearly pronounced for 5 and 10 microm silica particles. By the isolated effect of increased viscosity, the centre of the 10 microm particle zone was elevated to the streamline at 16% of the channel height. These experiments have shown that the influence of carrier liquid viscosity on HLF should be taken into account even at higher levels above the channel bottom, i.e. beyond the near-wall region. Further, it is shown that higher value of carrier liquid viscosity improves the separation of the model mixture in terms of time and resolution.

Fractionation, Field Flow↗