PubMed Health⌕ Search

PubMed · 1586880

Nucleofractis phacoemulsification through a small pupil.

Abstract

A small pupil is an added risk with any technique for cataract extraction. A prospective study involving 1880 consecutive cataract procedures performed by one surgeon between January and June 1990 was carried out to determine the incidence of small pupils (preoperative diameter of 4 mm or less) and the surgical risk with phacoemulsification and implantation of an intraocular lens (IOL) "in the bag." Thirty eyes (1.6%) were found to have a small pupil. All 30 eyes received an in-the-bag posterior chamber IOL, with no intraoperative complications such as anterior or posterior capsule tears. The need for iris-enlarging surgery was correlated with pupil size: such surgery was done in O of the 10 eyes with pupils measuring 4 mm, 1 of the 12 eyes with pupils measuring 3 to 3.5 mm and 4 of the 8 eyes with pupils measuring 2 to 2.5 mm. The author proposes that opening the capsule with a continuous tear and removing the cataract by means of phacoemulsification with nuclear fracturing (nucleofractis) constitutes safe, efficient surgical management of eyes with small pupils undergoing cataract extraction.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

H V Gimbel. 1992. Nucleofractis phacoemulsification through a small pupil.. https://pubmed.ncbi.nlm.nih.gov/1586880/

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Profile of clear corneal cataract incisions demonstrated by ocular coherence tomography.

PURPOSE: To examine the profile of clear corneal cataract incisions in the living eye using optical coherence tomography (OCT). SETTING: Private practice, Eugene, Oregon, USA. METHODS: The Zeiss Visante OCT anterior segment imaging system was used to study the profile of clear corneal cataract incisions, all in senior citizens. The OCT images of the operative eye were taken on the first postoperative day approximately 24 hours after surgery. The OCT images of clear corneal incisions were compared with an OCT image of a control eye, incisions without stromal hydration, and previous drawings of clear corneal incisions. RESULTS: In the images, the clear corneal incisions had an arcuate configuration rather than a straight line configuration, as previously indicated. This architecture appears to add greater stability as a result of a tongue-and-groove-like fit of the floor to the roof of the incision as well as an incision that is longer than the chord length that had previously been measured. Other findings include that stromal swelling, which facilitates sealing of these incisions by the endothelial pump, lasted for at least 24 hours. CONCLUSIONS: Results indicate an incision in the plane of the cornea with a chord length of at least 2.0 mm provides advantageous architecture for adequate self-sealing. Proper clear corneal incision construction resulted in an incision architecture that seemed to have increased stability and added safety, contributing to an absence of endophthalmitis for more than 10 years and 9000 cases in a single practice.

Cataract Extraction↗

Teaching and assessing competence in cataract surgery.

PURPOSE OF REVIEW: To review recent literature regarding innovative techniques, methods of teaching and assessing competence and skill in cataract surgery. RECENT FINDINGS: The need for assessment of surgical competency and the requirement of wet lab facilities in ophthalmic training programs are being increasingly emphasized. Authors have proposed the use of standardized forms to collect objective and subjective data regarding the residents' surgical performance. Investigators have reported methods to improve visualization of cadaver and animal eyes for the wet lab, including the use of capsular dyes. The discussion of virtual reality as a teaching tool for surgical programs continues. Studies have proven that residents trained on a laparoscopic simulator outperformed nontrained residents during actual surgery for both surgical times and numbers of errors. Besides virtual reality systems, a program is being developed to separate the cognitive portion from the physical aspects of surgery. Another program couples surgical videos with three-dimensional animation to enhance the trainees' topographical understanding. SUMMARY: Proper assessment of surgical competency is becoming an important focus of training programs. The use of surgical data forms may assist in standardizing objective assessments. Virtual reality, cognitive curriculum and animation video programs can be helpful in improving residents' surgical performance.

Cataract Extraction↗