Estimating partition coefficients for fuel-water systems: developing linear solvation energy relationships using linear solvent strength theory to handle mixtures.

Abstract

In many environmental transport problems, organic solutes partition between immiscible phases that consist of liquid mixtures. To estimate the corresponding partition coefficients, we evaluated the efficacy of combining linear solvation energy relationships (LSERs) developed for pure 1:1 systems via application of linear solvent strength theory. In this way, existing LSERs could be extended to treat solute partitioning from gasoline, diesel fuel, and similar mixtures into contacting aqueous mixtures. Unlike other approaches, this method allowed prediction of liquid-liquid partition coefficients in a variety of fuel-water systems for a broad range of dilute solutes. When applied to 37 polar and nonpolar solutes partitioning between an aqueous mixture and 12 different fuel-like mixtures (many including oxygenates), the root-mean-squared error was a factor of approximately 2.5 in the partition coefficient. This was considerably more accurate than application of Raoult's law for the same set of systems. Regulators and scientists could use this method to estimate fuel-water partition coefficients of novel additives in future fuel formulations and thereby provide key inputs for environmental transport assessments of these compounds.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

J Samuel Arey, Philip M Gschwend. 2005-04-15. Estimating partition coefficients for fuel-water systems: developing linear solvation energy relationships using linear solvent strength theory to handle mixtures.. https://doi.org/10.1021/es048901l

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Signal ratio amplification via modulation of resonance energy transfer: proof of principle in an emission ratiometric Hg(II) sensor.

Boradiazaindacene dyads designed as energy transfer casettes can be modified to signal cation concentrations ratiometrically. If the energy transfer efficiency is increased via changing spectral overlap on cation binding, an enhancement of emission signal ratios can be obtained. A larger range of ratios results in highly improved sensitivity to analyte concentrations. We demonstrate this approach in a de novo design of a novel and highly selective ratiometric chemosensor for Hg(II) ions.

Energy Transfer↗