PubMed Health⌕ Search

PubMed · 15890424

Cone-beam-CT guided radiation therapy: technical implementation.

Abstract

BACKGROUND AND PURPOSE: X-ray volumetric imaging system (XVI) mounted on a linear accelerator is available for image guidance applications. In preparation for clinical implementation, phantom and patient imaging studies were conducted to determine the irradiation parameters that would trade-off image quality, patient dose and scanning time. PATIENTS AND METHODS: The XVI image quality and imaging dose were benchmarked against those obtained with a helical CT scanner for a head and body phantom. The irradiation parameters were varied including the total imaging dose, number of projections, field of view, reconstruction resolution and use of a scatter rejection grid. We characterized the image quality based on relative contrast, noise, contrast to noise ratio (CNR) and point spread function (PSF). XVI scans of pelvis, head and neck and lung patients were acquired and submitted to a range of observers to identify the favorable reconstruction parameters. RESULTS: Phantom studies have demonstrated that a scatter rejection grid reduces photon scattering and improves the image uniformity. For the body phantom, the helical CT and the wide field XVI technique produce similar image quality, with surface doses of 0.025 and 0.044 Gy respectively. We have demonstrated that the local tomography technique improves the image contrast and the CNR while reducing the skin dose by 40-50% compared to the wide field technique. Clinical scans of head and neck, lung and prostate patients present good soft tissue contrast and excellent bone definition. CONCLUSIONS: With adjustment of irradiation parameters and an imaging surface dose of less than 0.05 Gy, high quality XVI images can be obtained for a phantom simulating the body thickness. XVI is currently feasible for image-guided treatments of head and neck, torso and pelvic areas using soft tissue and bony structures.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Daniel Létourneau, John W Wong, Mark Oldham, Misbah Gulam, Lindsay Watt, David A Jaffray, Jeffrey H Siewerdsen, Alvaro A Martinez. 2005. Cone-beam-CT guided radiation therapy: technical implementation.. https://doi.org/10.1016/j.radonc.2005.03.001

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Global Genomic Surveillance.

Global genomic surveillance has emerged as a foundational pillar of public health in the twenty-first century, enabling real-time tracking of pathogen evolution and informing outbreak response. This chapter examines the strategic architecture of global genomic surveillance, focusing on its application to arboviruses such as chikungunya virus (CHIKV). It explores the integration of genomic data with epidemiological, clinical, and environmental information within a One Health framework, while addressing critical challenges in governance, equity, and interoperability. The discussion covers the entire genomic surveillance workflow, from sample collection and sequencing to bioinformatic analysis and phylogenetic inference, and highlights the transformative role of artificial intelligence (AI) in predictive surveillance. By analyzing global initiatives, operational barriers, and emerging technologies, this chapter underscores the necessity of sustainable, equitable, and interoperable genomic systems to proactively address current and future infectious disease threats.

Humans↗

Systematic Dissection of Key Driver Perturbation Signatures in Single Cells via ECCITE-seq.

CRISPR screens, such as expanded CRISPR-compatible cellular indexing of transcriptomes and epitopes by sequencing (ECCITE-seq), enable the simultaneous measurement of transcriptomes, gRNA identity, and cell-surface protein expression at single-cell resolution to systematically interrogate gene function. This platform provides a powerful and scalable experimental approach for validating disease-associated regulators identified by large-scale association studies and other computational methods, including network-based analyses of multi-omics data. Here, as an example application, we describe an ECCITE-seq framework to characterize the transcriptomic consequences of perturbing multiple neuronal key driver genes associated with Alzheimer's disease (AD) in human-induced pluripotent stem cell (hiPSC)-derived neurons. More broadly, by integrating customized pooled gRNA libraries with different CRISPR effectors across multiple cell types, this approach allows for the assessment of the regulatory impact of candidate genes implicated in development and disease processes.

Humans↗

Identification of Genome-Wide Chromatin Structural Aberration in Cancer by Hi-C Analysis.

Aberrant three-dimensional genome organization is a hallmark of cancer, often driving oncogene activation through mechanisms such as enhancer hijacking. High-throughput chromosome conformation capture (Hi-C) maps these interactions on a genome-wide scale. Unlike earlier dilution-based methods, in situ Hi-C performs proximity ligation within intact nuclei, minimizing random ligation noise and enabling fine-scale structure detection. This chapter describes an optimized in situ Hi-C protocol tailored for cancer cell lines using MboI digestion and biotin-mediated pull-down to generate high-complexity libraries. We further outline a computational workflow that extends beyond standard topological mapping of compartments and topologically associating domains to identify cancer-specific aberrations. Specifically, we focus on detecting chromosomal rearrangements (structural variants) and characterizing the distinct circular topology of extrachromosomal DNA. This integrated experimental and analytical framework provides the necessary tools to dissect the spatial dysregulation underlying tumor evolution.

Humans↗