PubMed Health⌕ Search

PubMed · 15897846

Modified cheek retractor.

Abstract

The source did not provide an abstract. Follow the original record for more information.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Takafumi Chin. 2005. Modified cheek retractor.. https://doi.org/10.1016/j.tripleo.2005.02.061

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Fatal hyperthermia due to dental treatment.

A 12-year-old boy with mental retardation and cerebral palsy developed hyperthermia during dental treatment performed while he was conscious. During the treatment, he was highly excited, and shortly after completion of the procedure, general muscular spasms occurred. His axillary temperature was 41.6 degrees C then. He was transferred to another general hospital and there he was judged to have become afebrile and was discharged. His condition deteriorated during the night, and he was readmitted to the same hospital the following morning. The patient did not respond to the therapy and died from multiple organ failure on the 13th day. It was thought that hyperthermia had led to rhabdomyolysis and DIC. The cause of death is discussed. Hyperthermia in a handicapped patient is not always transient or benign, and can be life threatening.

Anesthesia, Dental↗

A comparison of the aspirating abilities of re-usable and partly disposable dental cartridge syringes in vitro.

OBJECTIVES: To compare the ability of re-usable and partly disposable dental cartridge syringes to aspirate in vitro. METHODS: A laboratory investigation comparing two re-usable (Astra and Rotor) and one partly disposable (Ultra Safety-plus) dental cartridge syringes. Forces needed to move the cartridge plunger and forces required to produce aspiration of Bonney's Blue dye were measured using an Instron testing machine. RESULTS: There were significant differences in the forces needed to produce aspiration in the different systems (F = 194, p<0.001). The Astra system needed the least force to produce aspiration. The forces required to aspirate in the Rotor and Ultra Safety-plus systems did not differ. Each system aspirated effectively in vitro at the initial aspiration manoeuvre. The forces available for subsequent aspiration attempts varied with the speed of cartridge plunger movement. The volume of local anaesthetic cartridge used did not affect the force needed to produce aspiration in the Ultra Safety-plus syringe. The method of testing free-flow of solution through the needle affected the force generated at subsequent plunger movements. CONCLUSIONS: The re-usable and partly disposable syringes investigated aspirated effectively at the initial aspiration manoeuvre. The force available to produce aspiration at subsequent attempts varies with the speed of injection. The method of testing free-flow of solution through the needle in a loaded syringe affects the force available at the first aspiration manoeuvre.

Anesthesia, Dental↗